BackgroundNeonatal mortality is a global challenge, with an estimated 1.3 million intrapartum stillbirths in 2015. The majority of these were found in low resource settings with limited options to intrapartum fetal heart monitoring devices. This trial compared frequency of abnormal fetal heart rate (FHR) detection and adverse perinatal outcomes (i.e. fresh stillbirths, 24-h neonatal deaths, admission to neonatal care unit) among women intermittently assessed by Doppler or fetoscope in a rural low-resource setting.MethodsThis was an open-label randomized controlled trial conducted at Haydom Lutheran Hospital from March 2013 through August 2015. Inclusion criteria were; women in labor, singleton, cephalic presentation, normal FHR on admission (120–160 beats/minute), and cervical dilatation ≤7 cm. Verbal consent was obtained.ResultsA total of 2684 women were recruited, 1309 in the Doppler and 1375 in the fetoscope arms, respectively. Abnormal FHR was detected in 55 (4.2%) vs 42 (3.1%). (RR = 1.38; 95%CI: 0.93, 2.04) in the Doppler and fetoscope arms, respectively. Bag mask ventilation was performed in 80 (6.1%) vs 82 (6.0%). (RR = 1.03; 95%CI: 0.76, 1.38) of neonates, and adverse perinatal outcome was comparable 32(2.4%) vs 35(2.5%). (RR = 0.9; 95%CI: 0.59, 1.54), in the Doppler and fetoscope arms, respectively.ConclusionThis trial failed to demonstrate a statistically significant difference in the detection of abnormal FHR between intermittently used Doppler and fetoscope and adverse perinatal outcomes. However, FHR measurements were not performed as often as recommended by international guidelines. Conducting a randomized controlled study in rural settings with limited resources is associated with major challenges.Trial registrationThis clinical trial was registered on April 2013 with registration number NCT01869582.
BackgroundFetal stethoscopes are mainly used for intermittent monitoring of fetal heart rate (FHR) during labor in low-income countries, where perinatal mortality is still high. Handheld Dopplers are rarely available and are dependent on batteries or electricity. The objective was to compare the Pinard stethoscope versus a new wind-up handheld Doppler in the detection of abnormal FHR.Materials and methodsWe conducted a randomized controlled study at Muhimbili National Hospital, Tanzania, from April 2013 to September 2015. Women with gestational age ≥37 weeks, cephalic presentation, normal FHR on admission, and cervical dilatation <7 cm were included. Primary outcome was abnormal FHR detection (<120 or >160 beats/min). Secondary endpoints were time to delivery, mode of delivery, and perinatal outcomes. χ2, Fisher’s exact test, Mann–Whitney test, and logistic regression were conducted. Unadjusted and adjusted odds ratios were calculated with respective 95% confidence interval.ResultsIn total, 2,844 eligible women were assigned to FHR monitoring with Pinard (n=1,423) or Doppler (n=1,421). Abnormal FHRs were more often detected in the Doppler (6.0%) versus the Pinard (3.9%) arm (adjusted odds ratio =1.59, 95% confidence interval: 1.13–2.26, p=0.008). Median (interquartile range) time from abnormal FHR detection to delivery was comparable between Doppler and Pinard, ie, 80 (60,161) and 89 (52,165) minutes, respectively, as was the incidence of cesarean delivery (12.0% versus 12.2%). The incidence of adverse perinatal outcomes (fresh stillbirths, 24-hour neonatal admissions, and deaths) was similar overall; however, among newborns with abnormal FHR delivered vaginally, adverse outcomes were less incident in Doppler (7 of 43 births, 16.3%) than in the Pinard arm (10 of 23 births, 43.5%), p=0.021.ConclusionIntermittent FHR monitoring using Doppler was associated with an increased detection of abnormal FHR compared to Pinard in a low-risk population. Time intervals from abnormal FHR detection to delivery were longer than recommended in both arms. Perinatal outcomes were better among vaginally delivered newborns with detected abnormal FHR in the Doppler arm.
BackgroundCriteria-based audits (CBA) have been used to improve clinical management in developed countries, but have only recently been introduced in the developing world. This study discusses the use of a CBA to improve quality of care among eclampsia patients admitted at a University teaching hospital in Dar es Salaam Tanzania.ObjectiveThe prevalence of eclampsia in MNH is high (≈6%) with the majority of cases arriving after start of convulsions. In 2004–2005 the case-fatality rate in eclampsia was 5.1% of all pregnant women admitted for delivery (MNH obstetric data base). A criteria-based audit (CBA) was used to evaluate the quality of care for eclamptic mothers admitted at Muhimbili National Hospital (MNH), Dar es Salaam, Tanzania after implementation of recommendations of a previous audit.MethodsA CBA of eclampsia cases was conducted at MNH. Management practices were evaluated using evidence-based criteria for appropriate care. The Ministry of Health (MOH) guidelines, local management guidelines, the WHO manual supplemented by the WHO Reproductive Health Library, standard textbooks, the Cochrane database and reviews in peer reviewed journals were adopted. At the initial audit in 2006, 389 case notes were assessed and compared with the standards, gaps were identified, recommendations made followed by implementation. A re-audit of 88 cases was conducted in 2009 and compared with the initial audit.ResultsThere was significant improvement in quality of patient management and outcome between the initial and re-audit: Review of management plan by senior staff (76% vs. 99%; P=0.001), urine for albumin test (61% vs. 99%; P=0.001), proper use of partogram to monitor labour (75% vs. 95%; P=0.003), treatment with steroids for lung maturity (2.0% vs. 24%; P=0.001), Caesarean section within 2 hours of decision (33% vs. 61%; P=0.005), full blood count (28% vs. 93%; P=0.001), serum urea and creatinine (44% vs. 86%; P=0.001), liver enzymes (4.0% vs. 86%; P=0.001), and specialist review within 2 hours of admission (25% vs. 39%; P=0.018). However, there was no significant change in terms of delivery within 24 hours of admission (69% vs. 63%; P=0.33). There was significant reduction of maternal deaths (7.7% vs. 0%; P=0.001).ConclusionCBA is applicable in low resource setting and can help to improve quality of care in obstetrics including management of pre-eclampsia and eclampsia.
Background. Pregnancy luteomas are rare, benign, ovarian neoplasms resulting from increased androgenic activity during pregnancy. Often, they occur asymptomatically and are only diagnosed incidentally during imaging or surgery: cesarean section or postpartum tubal ligation. Most common symptoms associated with pregnancy luteoma include acne, deepening of voice, hirsutism, and clitoromegaly. Most pregnancy luteomas regress spontaneously postpartum. Thus, the management of pregnancy luteomas depends on the clinical situation. Case. We report a case of 28-year-old gravida 2, para 1 who presented at 39 + 1 weeks of gestation with prolonged labor and delivered by emergency cesarean. Intraoperatively, a huge left ovarian mass was identified and resected, and tissue was sent for histopathology and a diagnosis of pregnancy luteoma was made after the pathological report. Conclusion. The present report emphasizes that pregnancy luteoma is a benign neoplasm and imprudent surgical intervention should be reserved. Proper imaging techniques, preferably MRI or ultrasonography that visualize the size of the ovary and reproductive hormonal profiles, would suffice for the diagnosis and management of pregnancy luteoma.
Background: Children living with HIV worldwide majority are infected through mother to child transmission of HIV (MTCT) acquired during pregnancy. Knowledge, attitude and behavioral changes are pivot tools towards success of any interventions. Objectives: To determine the effectiveness of counseling on HIV done in primary health facilities (PHF), level of knowledge gained and attitude changes towards PMTCT. Methods: A cross sectional study assessing pregnant women's knowledge and their attitude towards PMTCT was conducted in Temeke district from October 2010 to Jan 2011 using a structured questionnaire. Results: A total of 383 antenatal attendees were referred to Temeke district for management after counselled and tested for HIV in PHFs. Majority (86.9%) had primary education and good knowledge on MTCT. Correct timing of ARVs prophylaxis (15.7%) as preventive measures for MTCT was poor. Education and employment were associated with good knowledge on MTCT of HIV. Women had positive attitudes towards HIV counseling and testing, but stigma was a barrier to disclosure of one's serostatus. Conclusion: There is knowledge gap in routine PMTCT counseling among antenatal attendees in our PHFs. Effective counseling on PMTCT in the PHFs will bridge the identified knowledge gap and help in reduction of pediatric HIV. African Health Sciences 2013; 13(4): 914 -919 http://dx
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.