Timepix3 detectors are the latest generation of hybrid active pixel detectors of the Medipix/Timepix family. Such detectors consist of an active sensor layer which is connected to the readout ASIC (application specific integrated circuit), segmenting the detector into a square matrix of 256 × 256 pixels (pixel pitch 55 µm). Particles interacting in the active sensor material create charge carriers, which drift towards the pixelated electrode, where they are collected. In each pixel, the time of the interaction (time resolution 1.56 ns) and the amount of created charge carriers are measured. Such a device was employed in an experiment in a 120 GeV/c pion beam. It is demonstrated, how the drift time information can be used for "4D" particle tracking, with the three spatial dimensions and the energy losses along the particle trajectory (dE/dx). Since the coordinates in the detector plane are given by the pixelation (x,y), the x-and y-resolution is determined by the pixel pitch (55 µm). A z-resolution of 50.4 µm could be achieved (for a 500 µm thick silicon sensor at 130 V bias), whereby the drift time model independent z-resolution was found to be 28.5 µm.
The Timepix3—the latest generation of hybrid particle pixel detectors of Medipix family—yields a lot of new possibilities, i.e. a high hit-rate, a time resolution of 1.56 ns, event data-driven readout mode, and the capability of measuring the Time-over-Threshold (ToT - energy) and the Time-of-Arrival (ToA) simultaneously. This paper introduces a newly developed readout device for the Timepix3, called "Katherine", featuring a Gigabit Ethernet interface. The primary benefit of the Katherine is the operation of Timepix3 at long distance (up to 100 m) from computer or server, which is advantageous for the installation at beam lines, where the access is difficult or where radiation levels are too high for human interventions. The maximal hit-rate is limited by the bandwidth of the Ethernet connection (peer-to-peer connection; up to 16 Mhit/s). Since the Katherine interface is equipped with a processor of high computational power (ARM Cortex-A9 dual-core processor), it permits the use as a stand-alone (autonomous) radiation detector. The key features of the device are described in detail. These are the implemented high voltage power supply offering both polarities of bias voltage (up to ± 300 V), the automatic data sending to a sever via SSH, the automatic compensation of ToA values from columns with shifted matrix clock, etc. A dedicated control software was developed, which can be used for the detector preparation (sensor equalization, the DACs dependency scan, and the THL scan) and measurement control. Measured energy spectra from photon fields are shown.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.