The X-ray computed tomography (CT) measurement process suffers from a variety of error sources including geometrical misalignments of the CT imaging components: X-ray source focal spot, rotation stage, and X-ray detector. Effective correction of these misalignments demands accurate measurement of the instrument geometry. A common method to measure geometrical parameters involves radiographically imaging a reference object consisting of several high X-ray absorption spheres. The resulting projection images are used to solve the CT geometry of the instrument. Geometrical parameters can be solved either analytically or by minimization of reprojection errors. In this study, the minimization technique is chosen over analytical methods due to the relative versatility in its practical implementation. Various precautions must be taken when using minimization techniques and these are discussed. Errors in the data acquisition and subsequent minimization procedure introduce errors in the measured geometry and are investigated here. The geometrical measurement procedure is performed on simulated data using the Computed Tomography Calibration Tube (CT 2), a reference object that was designed to reduce sphere overlaps in the projected images while at the same time broadening the distribution of projected spheres across the detector area. It should be noted, however, that the proposed procedure can be implemented with any reference object consisting of high X-ray absorption spheres, provided the coordinate positions of the sphere centers in a local frame are known. Residual errors between the true (simulated) and measured geometrical parameters are shown to be negligible from tomographic reconstruction of datasets acquired in the presence of these residual errors.
A procedure for measuring the geometry of X-ray computed tomography (CT) instruments is applied to an experimental CT instrument. In this study, the geometrical measurement procedure is implemented with the CT 2 reference object, comprising steel spheres with known center positions in a local coordinate frame affixed to a cylindrical carbon fiber framework. The procedure can be implemented with other sphere-based reference objects, provided the sphere center coordinates are known. The effects of number of acquired projections and rotation mode (stepped or continuous) on the quality of measured geometrical parameters are studied. Finally, the output of the geometrical measurement procedure is used to inform the physical adjustment of the experimental CT instrument to its ideal alignment. The effectiveness of the measurement procedure to correctly determine the instrument geometry is demonstrated from dimensional measurements performed on a tomographically reconstructed validation object from radiographs acquired under initial (misaligned) and adjusted (aligned) instrument geometry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.