Controversy continues to surround the use of opioids in equine anaesthesia, with variable effects reported. This blinded clinical study aimed to investigate the influence of a low-dose fentanyl continuous rate infusion (CRI) on isoflurane requirements, parasympathetic tone activity (PTA), and anaesthetic parameters in horses during general anaesthesia. All of the twenty-two horses included in the research underwent a standard anaesthetic protocol. Eleven horses in the fentanyl group (Group F) received a loading dose of fentanyl at 6 µg/kg, followed by a CRI of 0.1 µg/kg/min during anaesthesia. A further 11 horses in the control group (Group C) received equivalent volumes of normal saline. Anaesthetic parameters and PTA index were recorded during anaesthesia. The achieved mean fentanyl plasma concentration was 6.2 ± 0.83 ng/mL. No statistically significant differences between groups were found in isoflurane requirements, MAP values, and mean dobutamine requirements. However, horses in Group F required a significantly lower dose of additional ketamine to maintain a sufficient depth of anaesthesia. Significantly higher PTA values were found in the fentanyl group. Further research is warranted to determine the limitations of PTA monitoring, and the influence of various anaesthetics on its values.
Case series summary This case series describes the neuromuscular blockade (NMB) following 0.15 mg/kg intravenous (IV) cisatracurium administration in 11 cats undergoing ophthalmological surgery and anaesthetised with isoflurane. Anaesthetic records were analysed retrospectively. Neuromuscular function was assessed by a calibrated train-of-four (TOF) monitor. Cats were 73 ± 53 months old, weighed 4 ± 1 kg and were of American Society of Anesthesiologists’ physical classification 2. Duration of anaesthesia and surgery were 144 ± 27 and 94 ± 24 mins, respectively. The lowest TOF count was zero in four cats, four in six cats and for one cat the TOF ratio never decreased below 31%. The time of onset was between 1 and 6 mins after the administration of cisatracurium and the mean duration of action was 20.4 ± 10.1 mins. Relevance and novel information Cisatracurium at a dose of 0.15 mg/kg IV did not consistently induce a TOF count of zero in all cats. The dose used in these cats did not produce any remarkable cardiovascular side effects. Although the NMB was not complete, the dose given was sufficient to produce central eyeball position, which was the goal of the ophthalmic surgeries.
A cockerel (Gallus gallus domesticus) was presented for lameness investigation. A CT scan of the left leg and a bone marrow biopsy were planned. Both procedures were performed under general anaesthesia and, before the biopsy was performed, a sciatic nerve block was achieved with levobupivacaine 0.5% (0.75 mg/kg), aided by an electrical nerve locator. The nerve was located through a lateral approach, with a motor response to stimulation similar to that described in mammals. The efficacy of the block was assessed as satisfactory during the procedure. Postoperatively, the pain was subjectively assessed, but no pain scales were employed, as none are validated for birds. No iatrogenic complications occurred; therefore, this nerve block could be considered as a part of a multimodal approach to perioperative pain management.
Different blood gas analyzers are used in equine practice. Every machine needs to be validated, as they have not been designed for use in horses. The aim of this study was to compare the newly marketed GEM5000 machine to the formerly validated epoc machine for blood gas analysis in horses. In this prospective, non-blinded, comparative laboratory analyzer study, 43 equine blood samples were analyzed on both analyzers and values were compared between the two machines via Lin’s concordance analysis, Passing–Bablok regression analysis and Bland–Altman plots. Duplicate measurements were conducted on the GEM5000 machine to evaluate precision. The GEM5000 failed to achieve the required precision for tHb, Hct and iCa2+, but achieved acceptable precision for all other parameters. Concordance correlation analysis revealed poor correlation for Na+, Cl−, iCa2+, K+, Hct and tHb, while there was an at least moderate agreement for all other parameters. Passing–Bablok regression revealed significant constant bias for pCO2, pO2, Cl−, and iCa2+ and significant proportional bias for pCO2, iCa2+ and SO2. Bland–Altman analysis revealed significant systematic bias for Na+, Cl−, iCa2+, K+, Hct, tHb and SO2. This study shows that while precision of the GEM5000 is good, values should not be used interchangeably with data obtained from other blood gas analyzers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.