Rechargeable implantable pulse generators (r-IPGs) have been available for spinal cord stimulation (SCS) claiming to offer a longer service life but demanding continuous monitoring and regular recharging by the patients. The aim of the study (DRKS00021281; Apr 7th, 2020) was to assess the convenience, safety, and acceptance of r-IPGs and their effect on patient lives under long-term therapy. Standardized questionnaires were sent to all chronic pain patients with a r-IPG at the time of trial. Primary endpoint was the overall convenience of the charging process on an ordinal scale from “very hard” (1 point) to “very easy” (5 points). Secondary endpoints were charge burden (min/week), rates of user confidence and complications (failed recharges, interruptions of therapy). Endpoints were analyzed for several subgroups. Data sets n = 40 (42% return rate) were eligible for analysis. Patient age was 57.2 ± 12.6 (mean ± standard deviation) years with the r-IPG being implanted for 52.1 ± 32.6 months. The overall convenience of recharging was evaluated as “easy” (4 points). The charge burden was 112.7 ± 139 min/week. 92% of the patients felt confident recharging the neurostimulator. 37.5% of patients reported failed recharges. 28.9% of patients experienced unintended interruptions of stimulation. Subgroup analysis only showed a significant impact on overall convenience for different models of stimulators (p < 0.05). Overall, SCS patients feel confident handling a r-IPG at high rates of convenience and acceptable effort despite high rates of usage-related complications. Further technical improvements for r-IPGs are needed.
Introduction: Rechargeable implantable pulse generators (r-IPGs) have been available for spinal cord stimulation (SCS) claiming to offer a longer service life but demanding continuous monitoring and regular recharging by the patients. The aim of the study (DRKS00021281; Apr 7th, 2020)of was to assess the convenience, safety, and acceptance of r-IPGs and their effect on patient lives under long-term therapy. Materials & Methods: Standardized questionnaires were sent to all chronic pain patients with a r-IPG at the time of trial. Primary endpoint was the overall convenience of the charging process on an ordinal scale from "very hard" (1 point) to "very easy" (5 points). Secondary endpoints were charge burden (minutes/week), rates of user confidence and complications (failed recharges, interruptions of therapy). Endpoints were analyzed for several subgroups. Results: n=40 data sets (42% return rate) were eligible for analysis. Patient age was 57.2 ± 12.6 (mean ± standard deviation) years with the r-IPG being implanted for 52.1 ± 32.6 months. The overall convenience of recharging was evaluated as "easy" (4 points). The charge burden was 112.7 ± 139 min/week. 92% of the patients felt confident recharging the neurostimulator. 37.5% of patients reported failed recharges. 28.9% of patients experienced unintended interruptions of stimulation. Subgroup analysis only showed a significant impact on overall convenience for different models of stimulators (p<0.05). Conclusion: Overall, SCS patients feel confident handling a r-IPG at high rates of convenience and acceptable effort despite high rates of usage-related complications. Further technical improvements for r-IPGs are needed.
Spinal cord stimulation (SCS) has been utilized for more than 50 years to treat refractory neuropathic pain. Currently, SCS systems with fully implantable pulse generators (IPGs) represent the standard. New wireless extracorporeal SCS (wSCS) devices without IPGs promise higher levels of comfort and convenience for patients. However, to date there are no studies on how charging and using this wSCS system affects patients and their therapy. This study is the first questionnaire-based survey on this topic focusing on patient experience. The trial was a single arm, open-label and mono-centric phase IV study. Standardized questionnaires were sent to all patients with a wSCS device in use at the time of trial. The primary endpoint was the convenience of the charging and wearing process scored on an ordinal scale from "very hard" (1) to "very easy" (5). Secondary endpoints included time needed for charging, the duration of stimulation per day and complication rates. Questionnaires of 6 out of 9 patients were returned and eligible for data analysis. The mean age of patients was 61.3 ± 6.7 (± SD) years. The duration of therapy was 20.3 ± 15.9 months (mean ± SD). The mean duration of daily stimulation was 17 ± 5.9 h (mean ± SD). n = 5 patients rated the overall convenience as "easy" (4) and n = 3 patients evaluated the effort of the charging process and wearing of the wSCS device as "low" (4). n = 5 patients considered the wearing and charging process as active participation in their therapy. n = 5 patients would choose an extracorporeal device again over a conventional SCS system. Early or late surgical complications did not occur in this patient collective. Overall, patients felt confident using extracorporeal wSCS devices without any complications. Effort to maintain therapy with this system was rated as low.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.