Ivabradine is currently approved to reduce heart rate in children with chronic heart failure and dilated cardiomyopathy. Ivabradine has also been used off-label in children to treat automatic tachyarrhythmias such as ectopic atrial tachycardia and junctional ectopic tachycardia. Adverse effects of ivabradine at physiological doses as well as its toxicity at supra-physiological doses have rarely been reported in adults. In children, weight-based dosing requires dilution of commercially available ivabradine oral solution for accuracy. We describe a case of ivabradine overdose in a newborn (treated for ectopic atrial tachycardia) secondary to inaccurate dosing leading to the infant receiving 10 times more drug than prescribed. This case highlights potential pitfalls of ivabradine prescription and preparation in children.
Objective : Our primary objective study was to evaluate the association between near-infrared spectroscopy (NIRS) and low cardiac output (LCO) in patients with single-ventricle physiology after stage 1 palliation. Methods : In this retrospective study, infants ≤6 months of age with single-ventricle physiology who underwent stage 1 palliation were included. Cerebral and renal NIRS values at various time intervals after surgery were compared between patients with low and normal cardiac output. LCO within the first 48 after surgery was defined as per the pediatric cardiac critical care consortium database. NIRS values were also compared with other adverse outcomes such as cardiac arrest, need for extracorporeal membrane oxygenation and mortality. The receiver operative characteristic curve was generated to determine an optimal cut-off NIRS value for detecting LCO. Results : Ninety-one patients with median (Interquartile range) age of 10 days (6–26) and weight of 3.3 kg (3–3.5) were included in the study. Cerebral NIRS at 1 h (41.2 vs. 49.5; P = 0.002), 6 h (44 vs. 52.2; P = 0.001), and 12 h (51.8 vs. 56; P = 0.025) was significantly lower in the grouP with LCO compared to no LCO. Cerebral NIRS at 6 h was independently associated with LCO (P = 0.018), and cerebral NIRS at 6 h ≤57% had 91% sensitivity and 72% specificity to detect LCO. Conclusions : Cerebral NIRS ≤57% at 6 h after surgery detected LCO after stage 1 palliation in single-ventricle patients. Cerebral or renal NIRS was not associated with adverse outcomes and therefore, may not be useful in predicting adverse outcomes in this population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.