Background: Cardiac surgery often represents the only treatment option in patients with infective endocarditis (IE). However, IE surgery may lead to a sudden release of inflammatory mediators, which is associated with the severity of postoperative organ dysfunction. We investigated the impact of hemoadsorption during IE surgery on postoperative organ dysfunction. Methods: This multi-center, randomized, non-blinded, controlled trial assigned patients undergoing cardiac surgery for IE to hemoadsorption [integration of CytoSorb® to cardiopulmonary bypass (CPB)] or control. The Primary outcome (ΔSOFA) was defined as the difference between the mean total postoperative sequential organ failure assessment score (SOFA), calculated maximally to the 9th postoperative day, and the basal SOFA score. The analysis was by modified intention-to-treat. A predefined inter-group comparison was done using a linear mixed model for ΔSOFA including surgeon and baseline SOFA as fixed effect covariates and with the surgical center as random effect. The SOFA score assesses dysfunction in six organ systems, each scored from zero to four. Higher scores indicate worsening dysfunction. Secondary outcomes were 30-day mortality, durations of mechanical ventilation, vasopressor and renal replacement therapy. Cytokines were measured in the first 50 patients. Results: Between January 17, 2018 and January 31, 2020, A total of 288 patients were randomly assigned to hemoadsorption (n=142) or control (n=146). Four patients in the hemoadsorption and two in the control group were excluded as they did not undergo surgery. The primary outcome ΔSOFA did not differ between the hemoadsorption and the control group (1.79 ± 3.75 and 1.93 ± 3.53, respectively, 95% CI: −1.30 to 0.83, p=0.6766). Mortality at 30 days (21% hemoadsorption vs 22% control, p=0.782), the durations of mechanical ventilation, vasopressor and renal replacement therapy did not differ between groups. Levels of IL-1β and IL-18 at the end of CPB were significantly lower in the hemoadsorption than in the control group. Conclusions: This randomized trial failed to demonstrate a reduction in postoperative organ dysfunction through intraoperative hemoadsorption in patients undergoing cardiac surgery for IE. Although hemoadsorption reduced plasma cytokines at the end of CPB, there was no difference in any of the clinically relevant outcome points.
Background: Transcatheter aortic valve replacement (TAVR) is an established treatment option for patients with severe symptomatic aortic stenosis (AS), and is most commonly performed through the transfemoral access route. Percutaneous access site closure can be achieved using dedicated plug-based or suture-based vascular closure device (VCD) strategies, but randomized comparative studies are scarce. Methods: The CHOICE-CLOSURE (Randomized Comparison of CatHeter-based Strategies fOr Interventional ACcess SitE CLOSURE during Transfemoral Transcatheter Aortic Valve Implantation) trial is an investigator-initiated, multicenter study, in which patients undergoing transfemoral TAVR were randomly assigned to vascular access site closure using either a pure plug-based technique (MANTA, Teleflex, Wayne, Pennsylvania) with no additional VCDs or a primary suture-based technique (ProGlide, Abbott Vascular, Abbott Park, Illinois) potentially complemented by a small-plug. The primary endpoint consisted of access-site or access-related major and minor vascular complications during index hospitalization, defined according to the Valve Academic Research Consortium-2 criteria. Secondary endpoints included the rate of access-site or access-related bleeding, VCD failure, and time to hemostasis Results: A total of 516 patients were included and randomized. The mean age of the study population was 80.5±6.1 years, 55.4% were male, 7.6% of patients had peripheral vascular disease, and the mean Society of Thoracic Surgeons score was 4.1±2.9%. The primary endpoint occurred in 19.4% (50/258) of the pure plug-based group and 12.0% (31/258) of the primary suture-based group (relative risk [RR]: 1.61, 95% confidence interval [CI]: 1.07-2.44, p=0.029). Access-site or access-related bleeding occurred in 11.6% vs. 7.4% (RR: 1.58, 95%CI: 0.91-2.73, p=0.133) and device failure in 4.7% vs. 5.4% (RR: 0.86, 95%CI: 0.40-1.82, p=0.841) in the respective groups. Time to hemostasis was significantly shorter in the pure plug-based group (80 [32, 180] vs. 240 [174, 316] seconds, p<0.001). Conclusions: Among patients treated with transfemoral TAVR, a pure plug-based vascular closure technique using the MANTA VCD is associated with a higher rate of access-site or access-related vascular complications but a shorter time to hemostasis compared to a primary suture-based technique using the ProGlide VCD.
Background. Transapical, beating heart, off-pump implantation of neochordae for repair of mitral valve (MV) prolapse is of increasing interest. The aim of this study was to evaluate long term results for MV repair using the NeoChord system (NeoChord, St. Louis Park, MN).Methods. Six patients underwent treatment for severe primary mitral regurgitation (MR) with the NeoChord DS1000 system as part of the initial device safety and feasibility Transapical Artificial Chordae Tendinae (TACT) trial at our institution
BackgroundInfective endocarditis (IE) after transcatheter aortic valve replacement is a devastating complication associated with a high mortality. Our objective was to determine the impact of cardiac surgery (CS) and antibiotics (IE‐CS) compared with medical treatment with antibiotics only (IE‐ABx) on 1‐year mortality in patients developing IE after transcatheter aortic valve replacement.Methods and ResultsPatients developing IE after transcatheter aortic valve replacement were included in this retrospective analysis. All‐cause 1‐year mortality was the primary end point. A total of 20 patients underwent IE‐CS compared with 44 patients treated by IE‐ABx. In this unmatched cohort, patients treated by IE‐ABx were older (P=0.006), had a higher Society of Thoracic Surgeons score (P=0.029), and more often had severe chronic kidney disease (P=0.037). One‐year mortality was not different between groups (IE‐CS versus IE‐ABx, 65% versus 68.2%; P=0.802). The rate of any complication during treatment was higher in the IE‐CS group (P=0.024). In a matched cohort, baseline characteristics were not significantly different. All‐cause 1‐year mortality was not different between groups (IE‐CS versus IE‐ABx, 65% versus 75%; P=0.490). A Cox regression analysis revealed any indication for surgery (hazard ratio, 6.20; 95% confidence interval, 1.80–21.41; P=0.004), sepsis on admission (hazard ratio, 4.03; 95% confidence interval, 1.97–8.24; P<0.001), and mitral regurgitation ≥2 (hazard ratio, 2.91; 95% confidence interval, 1.33–6.37) as factors associated with 1‐year mortality.ConclusionsIn patients developing IE after transcatheter aortic valve replacement, mortality was predicted by the severity of IE and concomitant mitral regurgitation. In this small, and therefore statistically limited, but high‐risk patient cohort, CS provided no significant mortality benefit compared with medical therapy. Individual decision making by a “heart and endocarditis team” is necessary to offer those patients the most reasonable treatment option.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.