Background:The cytoskeleton contributes to receptor-initiated signaling and has been linked to force-regulated integrin activation. Results: Disrupting cytoskeletal interactions of PSGL-1 or ␣ L  2 does not impair slow rolling of leukocytes on P-selectin and ICAM-1.
Conclusion:The cytoskeleton is not required for PSGL-1-initiated signals to extend ␣ L  2 . Significance: Signals can "prime" integrins without the cytoskeleton.
Microfluidic cell adhesion assays have emerged as a means to increase throughput as well as reduce the amount of costly reagents. However as dimensions of the flow chamber are reduced and approach the diameter of a cell (D(c)), theoretical models have predicted that mechanical stress, force, and torque on a cell will be amplified. We fabricated a series of microfluidic devices that have a constant width:height ratio (10:1) but with varying heights. The smallest microfluidic device (200 μm ×20 μm) requires perfusion rates as low as 40 nL/min to generate wall shear stresses of 0.5 dynes/cm(2). When neutrophils were perfused through P-selectin coated chambers at equivalent wall shear stress, rolling velocities decreased by approximately 70 % as the ratio of cell diameter to chamber height (D(c)/H) increased from 0.08 (H = 100 μm) to 0.40 (H = 20 μm). Three-dimensional numerical simulations of neutrophil rolling in channels of different heights showed a similar trend. Complementary studies with PSGL-1 coated microspheres and paraformaldehyde-fixed neutrophils suggested that changes in rolling velocity were related to cell deformability. Using interference reflection microscopy, we observed increases in neutrophil contact area with increasing chamber height (9-33 %) and increasing wall shear stress (28-56 %). Our results suggest that rolling velocity is dependent not only on wall shear stress but also on the shear stress gradient experienced by the rolling cell. These results point to the D(c)/H ratio as an important design parameter of leukocyte microfluidic assays, and should be applicable to rolling assays that involve other cell types such as platelets or cancer cells.
Gastrointestinal bleeding occurs in 20-30% of patients receiving ventricular assist devices (VADs) due, in part, to acquired von Willebrand syndrome. We examined factors to optimize a benchtop method to quantify changes in von Willebrand Factor (VWF) multimer distribution and function in VADs, then applied them to evaluate commercially available devices. Human plasma was circulated through flow loops with VADs. Several experimental conditions were examined, including temperature, viscosity, and enzyme inhibition. Samples were analyzed for VWF collagen-binding activity (VWF:CB) and VWF antigen level. von Willebrand Factor multimer profiles were quantified using gel electrophoresis, near-infrared in-gel visualization, and densitometric analysis. The VWF:CB/antigen ratio in the HeartMate II, CentriMag, and HVAD exhibited average decreases of 46%, 44%, and 36% from baseline after 360 minutes of operation. High molecular weight (hVWF) multimer loss occurred within 30 minutes, although the Levacor and control loop profiles were unchanged. Varying temperature and viscosity altered hVWF degradation rate, but not the final results. Inhibition of ADAMTS13 can potentially distinguish mechanoenzymatic cleavage of VWF from mechanical degradation. We developed a repeatable benchtop method to evaluate VWF compatibility of VADs similar to hemolysis testing that can be adopted for preclinical VAD evaluation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.