High tibial osteotomy (HTO) is commonly used for genu varum deformity in young and active patients. Corrective valgus osteotomy may however lead to an oblique joint line in cases of associated femur varum or absence of tibia vara. The over-correction, needed to obtain good long-term clinical results, may increase the obliquity even more. To avoid this drawback, the authors suggest use of an accurate and reproducible radiological protocol including at least a standing AP long-leg X-ray to measure not only the hip-knee-ankle (HKA) angle but also the medial distal femoral mechanical angle (MDFMA) and the medial proximal tibial mechanical angle (MPTMA). These measures will guide the surgeon to choose the best indication, including HTO, double level osteotomy (DLO) and distal femoral osteotomy (DFO). Computer-navigation of the osteotomies is the best choice to achieve the preoperative goal. This paper will present the pre-and perioperative protocols of HTO and DLO and the rationale behind this way of thinking.
The purpose of this study was twofold: to evaluate the radiological and clinical results of 33 total knee arthroplasties (TKA) implanted between January 1993 and March 2005, to replace failed medial unicompartmental knee arthroplasty (UKA), and to develop a strategy to deal with bone defects in the tibial plateau. Failure was due to: tibial loosening (15 cases), femoral loosening (five cases), femoral and tibial loosening (two cases), polyethylene wear (five cases), lateral compartment osteoarthritis (two cases), patellofemoral osteoarthritis (two cases), laxity and PE dislocation (one case), and sepsis in one case. In 12 cases the tibial bone defect was filled with a metallic wedge, in seven we used an allograft (femoral head), and in one we used both. We report the results of 27 cases (five patients died and one was lost to follow-up). The mean follow-up was 73±41.7 months (range, 8-153) and the global IKS score was 166.72±21.3 points (range, 128-200). X-rays of the eight allografts showed osteointegration in all cases and no radiolucency was noted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.