Purpose
The purpose of this study was to assess the clinical and radiological outcomes of an arthroscopically assisted fixation of type IIB fractures using a double button device.
Methods
Twenty‐one patients with a type IIB displaced fracture of the clavicle who received an arthroscopically assisted fixation using a double button device were enrolled from 2009 to 2011. Clinical assessment included the patient's demographics, cause of injury, delay before surgery, time for surgery, time before resuming work and sports, the Shoulder and Hand (QuickDASH) score, the Constant–Murley score and the visual pain analogue scale (VAS). Radiological examination consisted of anteroposterior and axillary radiographs.
Results
The median age of patients was 33 years (range 18–67). Mean follow‐up was 35 ± 8.9 months (range 24–51 months). The average delay before surgery was 3 days (range 1–7). At final follow‐up, the mean QuickDASH score, Constant score and VAS were respectively 3.2 ± 6 (range 0–25), 94.8 ± 9.9 (range 62–100) and 0.5 ± 1.2 (range 0–4). Seventeen (81 %) patients were able to resume work, including heavy manual labour, and to resume their sport activities as well. Postoperative complications included one transient adhesive capsulitis, a symptomatic acromioclavicular joint osteoarthritis and an implant failure with nonunion. Bony union was achieved in all other patients.
Conclusion
This study has demonstrated that the arthroscopic treatment using a double button device was effective at providing a satisfactory functional outcome, minimizing the risk of complications and presenting low implant failure and low nonunion rates in patients with Neer type IIB fractures of the distal clavicle. Such results lead us to consider this minimally invasive technique as a first‐choice treatment.
Level of evidence
IV.
Pharyngeal complications due to anterior cervical spine surgery (ACSS) are not rare. We describe the case of a traction diverticulum of the hypopharynx after ACSS, a complication that has not yet been reported. We discuss the possible mechanism. A review of the complications of ACSS that are of interest to the otolaryngologist is included.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.