The coronavirus disease 2019 (COVID-19) represents a global concern of public health caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Its clinical manifestations are characterized by a heterogeneous group of symptoms and pictures (ranging from asymptomatic to lethal courses). The prevalence of conjunctivitis in patients with COVID-19 is at present controversial. Although it has been reported that only 0.9% developed signs of conjunctivitis, other report indicates that up to 31.6% of hospitalized patients had conjunctivitis. Considering the widespread use of topical ophthalmic medications (e.g., eye drops) by the general population, for various reasons (e.g., artificial tears, anti-glaucoma medications, topical antibiotics, etc.), the existence of their side effects as antiviral action should be investigated in-depth because it could possibly explain the aforementioned controversial data and represent a potential antiviral treatment for SARS-CoV-2 replication/diffusion on the ocular surface. Here, we discuss and elucidate the antiviral side effect of many eye drops and ophthalmic ointments commonly used for others purposes, thus showing that these secondary effects (not to be confused with the ‘adverse effects’) might be of primary importance in a number of viral infections (e.g., those for which there is no validated treatment protocol), according to a drug repurposing approach. Some active ingredients or excipients described here have activity against other types of viruses, thus suggesting potential broad-spectrum applications.
In the last few decades, the ocular surface and the tear film have been noninvasively investigated in vivo, in a three-dimensional, high resolution, and real-time mode, by optical coherence tomography (OCT). Recently, OCT technology has made great strides in improving the acquisition speed and image resolution, thus increasing its impact in daily clinical practice and in the research setting. All these results have been achieved because of a transition from traditional time-domain (TD) to Fourier-domain (FD) technology. FD-OCT devices include a spectrometer in the receiver that analyzes the spectrum of reflected light on the retina or ocular surface and transforms it into information about the depth of the structures according to the Fourier principle. In this review, we summarize and provide the state-of-the-art in FD-OCT imaging of the ocular surface system, addressing specific aspects such as tear film dynamics and epithelial changes under physiologic and pathologic conditions. A theory on the dynamic nature of the tear film has been developed to explain the variations within the individual compartments. Moreover, an integrative model of tear film behavior during the inter-blink period and visual fixation is proposed.
The aim of this meta-analysis was to collect data from randomized trials in burn patients and to analyze them with a meta-analytic approach to give a clear message of potential advantages of nanocrystalline silver (NC) versus older silver formulations (SS). A review of all-English prospective randomized trials that compared NC versus silver sulfadiazine or silver nitrate was conducted. Primary outcome was the evaluation of differences in the infection rate of burns. Secondary outcomes were the eventual differences in the pain experienced during medications, the length of hospitalization (LOS) and costs. Five articles that met the inclusion criteria were selected (n = 285 patients). The NC group had a significant lower incidence of infections compared with the SS group (9.5% vs. 27.8%, odds ratio: 0.14 [95% CI: 0.06-0.35]; chi2 test, P < 0.001), with a 2.9-fold decrease of the risk. Not all studies investigated the pain during change of dressings, LOS and costs. However, when data were available, these showed lower costs (US $1533 per patient for the SS group and US $946 per patient for the NC group) and decreased pain values in the NC group (Hedges' G: -1.44 [95% CI: -1.86/-1.01]; P < 0.0001), while contrasting results were obtained for LOS. Nanocrystalline silver is a relatively new product with a significant stronger antimicrobial activity compared with older formulations. Its long lasting properties reduce dressing change frequency and are probably responsible for the decreased pain and the minor costs experienced.
Background Despite the XEN gel stent low-risk profile, various complications following the implant have been described, including internal and external occlusion, with a consequent postoperative rise in intraocular pressure (IOP). In this case report we aimed to present a XEN45 stent internal occlusion successfully treated by trimming in situ its proximal end with a 25 G vitreous scissors using a bimanual technique. Case presentation A 63-year-old male patient affected by primary open angle glaucoma (IOP = 25 mmHg) and a full thickness macular hole in his right eye, underwent ab-interno Xen gel stent implantation and, 1 month later, a 25 G vitrectomy surgery. Despite a significant IOP reduction after stent implant, 6 days after vitrectomy, IOP increased (25 mmHg) and the conjunctival bleb flattened following occlusion of stent internal ostium by a clot of presumed fibrinous material. The Nd:YAG laser failed to remove the clot, so that we decided to snip a small bit of the proximal end of the Xen tube (about 0,5 mm length) with a 25 G vitreous scissors, using a bimanual technique. In the postoperative day 1 and month 1, the IOP was 8 mmHg and 12 mmHg, respectively. The Anterior Segment OCT confirmed a functional, layered, filtering bleb, and the normal appearance and patency of the XEN proximal segment. No side effects from the intervention were observed. Conclusions Ab interno trimming with vitreous scissors of the occluded proximal end of the XEN stent may represent a safe, rapid and efficient method to restore aqueous humor subconjunctival drainage.
Evaluation of angular and linear measurements, derived from both photographic and cephalometric material, allowed the authors to compare the two groups of patients and the modifications of the nasal region. These results are then compared with those available from current scientific literature so as to define the predictability of nasal shape modification. In conclusion, it is inadvisable to perform rhinoplasty at the time of orthognathic surgery to correct pre-existing defects, such as a dorsal hump, a nasal base that is too wide or too narrow, a nasal pyramid deviation, or other esthetic defects resulting from orthognathic surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.