Background. Fine-needle aspiration biopsy (FNAB) is diagnostic standard for thyroid nodules. However, the influence of adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules is not known well. Objectives. To assess the factors affecting adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules. Methods. Three hundred and forty-nine consecutive US-guided FNAB procedures were performed in 344 patients with subcentimeter thyroid nodules. The adequate sample rate was analyzed for all nodules on the basis of nodule-related and technical factors. The factors affecting adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules were determined by multivariate logistic regression. Results. The adequate sample rate increased with larger nodules (72.7% for 3–6 mm nodules and 84.9% for 7–10 mm nodules (P=0.007)). The adequate sample rate was 63.9%, 81.3%, and 90.6% in nodules with macrocalcifcation, microcalcification, and no calcification, respectively (P<0.001). The adequate sample rate was 71.8% for biopsies performed with a perpendicular needle path and 85.0% with a parallel needle path (P=0.004). The significant factors affecting adequate sample rate of US-guided FNAB for subcentimeter thyroid nodules were nodule size (P<0.001; odds ratio (OR) for 7–10 mm nodules was approximately 3.0 times higher than that for 3–6 mm nodules), calcification (P<0.001; OR for nodules without calcification was approximately 5.3 times higher than that for the nodules with macrocalcification), and needle path (P=0.044; OR for the use of the parallel needle path was about 1.8 times higher than that for the perpendicular needle path). Conclusion. Nodule size, calcification, and needle path were the determinants of sample adequacy. The adequate sample rate was higher in larger nodules, in nodules without calcification, and upon using a parallel needle path for biopsy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.