Postinflammatory hyperpigmentation (PIH) is the most common adverse effect of laser treatment in dark-skinned individuals. Little is known whether PIH can be prevented or minimised. The objective of this study was to investigate the effect of short-term application of topical corticosteroids on the incidence of PIH after ablative fractional resurfacing in Asians. Forty subjects with skin phototype IV and atrophic acne scars were treated with a fractional CO2 laser on both sides of the face. Post-operatively, clobetasol propionate 0.05% ointment was applied to one randomly selected side of the face for the first 2 days, followed by an application of petrolatum jelly for the rest of the week (petrolatum was applied to the other side for 7 days). Assessments on the clinical outcome, the wound healing process and the occurrence of PIH were obtained once weekly for the first month and at 2 and 3 months post-treatment. The side of the face treated with petrolatum alone had significantly (p < 0.001) higher incidence of PIH (75%) after laser irradiation than the side of the face treated with topical corticosteroids and petrolatum (40%). The PIH occurring on the petrolatum-treated sides had significantly higher intensity (p < 0.001) and was spread over a significantly larger area (p < 0.001), compared with the corticosteroid- and petrolatum-treated sides. In conclusion, a short-term application of topical corticosteroids postoperatively is associated with a decreased risk of PIH after ablative fractional resurfacing.
A large proportion of the jewelry sold in Thai markets release nickel or cobalt.
BackgroundDaily bathing with antiseptic cleansers are proposed by some physicians as an adjunctive management of atopic dermatitis (AD). As atopic skin is sensitive, selection of cleansing products becomes a topic of concern.ObjectiveOur purpose is to evaluate the pH of various antiseptic body cleansers to give an overview for recommendation to patients with AD.MethodsCommonly bar and liquid cleansers consisted of antiseptic agents were measured for pH using pH meter and pH-indicator strips. For comparison, mild cleansers and general body cleansers were also measured.ResultsAll cleansing bars had pH 9.8-11.3 except syndet bar that had neutral pH. For liquid cleansers, three cleansing agents had pH close to pH of normal skin, one of antiseptic cleansers, one of mild cleansers and another one of general cleansers. The rest of antiseptic cleansers had pH 8.9-9.6 while mild cleansers had pH 6.9-7.5. Syndet liquid had pH 7 and general liquid cleansers had pH 9.6.ConclusionThe pH of cleanser depends on composition of that cleanser. Adding antiseptic agents are not the only factor determining variation of pH. Moreover, benefit of antiseptic properties should be considered especially in cases of infected skin lesions in the selection of proper cleansers for patients with AD.
Introduction: Monopolar radiofrequency (MRF) is a valuable modality for tightening and contouring mild-to-moderate facial skin laxity. Few studies have evaluated new-generation MRF devices for lower facial laxity in Asians. This study aims to evaluate the efficacy and safety of MRF for treating lower facial laxity in Asians. Methods: This prospective cohort study enrolled 30 volunteers with Fitzpatrick Skin Types III-V and mild-to-moderate skin laxity. Subjects received a single MRF treatment. Self-assessments and adverse events were recorded. Two blinded dermatologists graded improvements (6-point scale) after treatment and 1, 3, and 6 months later. Results: All subjects completed the study. Treatment energy levels ranged from 2 to 4. The average number of shots was 412 ± 49, delivered in 3-4 passes with 15-30% overlap. All patients reported improvement in lower facial laxity immediately after treatment. Most patients had mild-to-moderate improvement over the 6-month follow-up. Continuous improvement was observed at the 1-, 3-, and 6-month follow-ups (P \ 0.01). Significant improvement was seen at the 6-month followup compared with the 1-month follow-up (P \ 0.01). Subjects tolerated the procedure well: the average pain score was 3.13 out of 10, and no serious adverse events were observed. Conclusions: The new-generation MRF device we tested was effective and safe for mild-tomoderate lower facial laxity in Asian skin. The latest MRF technology offers improved safety to prevent complications. Appropriate patient selection, setting, and protocols are mandatory to achieve optimal clinical outcomes. The Trial Registration Number: TCTR20 210326002.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.