OBJECTIVE:We studied the validity and reproducibility of a new abdominal ultrasound protocol for the assessment of intraabdominal adipose tissue. MEASUREMENTS: Intra-abdominal adipose tissue was assessed by CT, MRI, anthropometry and ultrasonography on a single day. By ultrasonography the distance between peritoneum and lumbar spine was measured using a strict protocol, including the location of the measurements, pressure on the transducer and respiration. All measurements were repeated after 3 months. RESULTS: The study population consisted of 19 overweight patients with a body mass index (BMI) of 32.9 kg=m 2 (s.d. 3.7), intra-abdominal adipose tissue on CT 140.1 cm 2 (s.d. 55.9), and a mean ultrasound distance of 9.8 cm (s.d. 2.5). There was a strong association between the CT and ultrasonographic measures: Pearson correlation coefficient was 0.81 (P < 0.001). The correlation between ultrasound and waist circumference was 0.74 (P < 0.001), the correlation between CT and waist circumference was 0.57 (P ¼ 0.01). Ultrasound appeared a good method to diagnose intra-abdominal obesity: the area under the ROC curve was 0.98. During the follow-up period of 3 months, the patients lost on average almost 3 kg of body weight. The correlation coefficient between changes in intra-abdominal adipose tissue assessed by CT and ultrasound was 0.74 (P < 0.001). The correlation coefficient of the mean ultrasound distance assessed by two different sonographers at baseline was 0.94 (P < 0.001), the mean difference 0.4 cm (s.d. 0.9), and the coefficient of variation 5.4%, indicating good reproducibility of the ultrasound measurements. CONCLUSIONS: The results of this validation study show that abdominal ultrasound, using a strict protocol, is a reliable and reproducible method to assess the amount of intra-abdominal adipose tissue and to diagnose intra-abdominal obesity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.