SUMMARYCombined cycle power plants (CCPPs) have an important role in power generation. The objective of this paper is to evaluate irreversibility of each part of Neka CCPP using the exergy analysis. The results show that the combustion chamber, gas turbine, duct burner and heat recovery steam generator (HRSG) are the main sources of irreversibility representing more than 83% of the overall exergy losses. The results show that the greatest exergy loss in the gas turbine occurs in the combustion chamber due to its high irreversibility. As the second major exergy loss is in HRSG, the optimization of HRSG has an important role in reducing the exergy loss of total combined cycle. In this case, LP-SH has the worst heat transfer process.The first law efficiency and the exergy efficiency of CCPP are calculated. Thermal and exergy efficiencies of Neka CCPP are 47 and 45.5% without duct burner, respectively. The results show that if the duct burner is added to HRSG, these efficiencies are reduced to 46 and 44%. Nevertheless, the results show that the CCPP output power increases by 7.38% when the duct burner is used.
SUMMARYThe objective of this paper is to perform the energy, exergy and exergoeconomic analysis for the Hamedan steam power plant. In the first part of the paper, the exergy destruction and exergy loss of each component of this power plant is estimated. Moreover, the effects of the load variations and ambient temperature are calculated in order to obtain a good insight into this analysis. The exergy efficiencies of the boiler, turbine, pump, heaters and the condenser are estimated at different ambient temperatures. The results show that energy losses have mainly occurred in the condenser where 306.9 MW is lost to the environment while only 67.63 MW has been lost from the boiler. Nevertheless, the irreversibility rate of the boiler is higher than the irreversibility rates of the other components. It is due to the fact that the combustion reaction and its high temperature are the most significant sources of exergy destruction in the boiler system, which can be reduced by preheating the combustion air and reducing the air-fuel ratio. When the ambient temperature is increased from 5 to 241C, the irreversibility rate of the boiler, turbine, feed water heaters, pumps and the total irreversibility rate of the plant are increased. In addition, as the load varies from 125 to 250 MW (i.e. full load) the exergy efficiency of the boiler and turbine, condenser and heaters are increased due to the fact that the power plant is designed for the full load. In the second part of the paper, the exergoeconomic analysis is done for each component of the power plant in order to calculate the cost of exergy destruction. The results show that the boiler has the highest cost of exergy destruction. In addition, an optimization procedure is developed for that power plant. The results show that by considering the decision variables, the cost of exergy destruction and purchase can be decreased by almost 17.11%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.