The revolution of internet and specifically mobile internet has occurred at a blinding pace over the last decade. With the advent of smart phones, the hand held device has become much more than a medium of voice calling. Healthcare has been catching up with the digital revolution in the form of Hospital Information System and Laboratory Information System. However, the advent of instant messaging services, which are abundantly used by the youth, can be used to improve communication and coordination among the various stake holders in the healthcare sector. We have tried to look at the impact of using the WhatsApp messenger service in the laboratory management system, by forming multiple groups of the various subsections of the laboratory. A total of 35 members used this service for a period of 3 months and their response was taken on a scale of 1 to 10. There was significant improvement in the communication in the form of sharing photographic evidence, information about accidents, critical alerts, duty rosters, academic activities and getting directives from seniors. There was also some increase in the load of adding information to the application and disturbance in the routine activities; but the benefits far outweighed the minor hassles. We thereby suggest and foresee another communication revolution which will change the way information is shared in a healthcare sector, with hospital specific dedicated apps.
Background Minimal/measurable residual disease (MRD) testing by flow cytometry (FC) has been proposed as a potential surrogate clinical endpoint in plasma cell myeloma (PCM) clinical trials. As a result, effort has gone into standardizing this approach on PCM patients. Aims To assess inter‐laboratory variation in FC MRD testing of PCM patients in an independent inter‐laboratory study. Methods A dilution series of five stabilized bone marrow samples manufactured to contain 0%, 0.1%, 0.01%, 0.001%, and 0.0001% neoplastic plasma cells (PCs) were tested blind, using standardized FC PCM MRD assays by 10 international laboratories. Results Laboratories' assays broadly adhered to the consensus guidelines; however, some deviations were identified in panel design, fluorochrome conjugates, and lysis reagents. Despite this, all laboratories that returned results detected neoplastic PCs down to 0.001% of leucocytes. 6/8 laboratories detected neoplastic PCs at a level of 0.0001%. Quantitative data returned by laboratories showed good consensus and linearity with increasing variation at lower levels of MRD. However, examples of analytical and post analytical error were identified. Summary/Conclusion Broadly standardized PCM MRD FC assays can attain the lower limit of detection (LOD) required by current and future clinical trials, an important consideration in establishing PCM MRD testing as a surrogate clinical marker in PCM clinical trials. Laboratories' assays showed good linearity, encouraging the prediction of survival based on log reduction in neoplastic PC populations in future clinical trials. However, the deviations from consensus guidelines identified in this study would suggest that if PCM MRD assays are further standardized interlaboratory variation could be reduced. © 2018 International Clinical Cytometry Society
The current case was positive for CD103, CD11c, CD25, and CD123 which has led the diagnosis to be of typical HCL. With the extensive literature review we found that only 26 cases of hairy cell leukemia [HCL and HCL-v] bearing CD5 expression have been reported so far. The positivity of CD5 is more common in HCL-v as compared to HCL. Additional prospective studies of CD5+ HCL and its variants are required to show whether they are a clinically significant subgroup of lymphoid malignancies. © 2016 International Clinical Cytometry Society.
Flow cytometry has been traditionally used to diagnose leukaemia and lymphoma in peripheral blood, bone marrow, body fluids, and tissue samples. The diagnosis of a malignant epithelial tumour is usually made by correlation between histopathologic appearance and the use of immunohistochemical staining. A CE approved BerEP4 antibody (anti-EpCAM, CD326) is available for flow cytometric testing, but has been evaluated predominantly in body fluids in the current literature. In this study, we have evaluated the performance of this antibody in detecting the presence of epithelial cells in tissue samples which have traditionally been reported as CD45 negative cells by flow cytometry. Among the 42 cases studied, 21 (50%) were found to be positive for CD326, thereby suggesting epithelial differentiation. The results had good concordance rates (97.6%) with final histopathological diagnosis. The results clearly show that flow cytometric testing for BerEP4 (CD326) can be a useful method for diagnosing nonhaematological malignancies that are poorly differentiated. As this is a rapid method for identifying epithelial differentiation, it can help the histopathologists tailor and rationalise the immunohistochemical panel, with the potential benefits of improving reporting times and work-flow in the laboratory. © 2017 International Clinical Cytometry Society.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.