In the present study, a facility, i.e., a mechanical deflection system (MDS), was established and applied to assess the long-term reliability of the solder joints in plastic ball grid array (BGA) assembly. It was found that the MDS not only quickly assesses the long-term reliability of solder joints within days, but can also mimic similar failure mechanisms in accelerated thermal cycling (ATC) tests. Based on the MDS and ATC reliability experiments, the acceleration factors (AF) were obtained for different reliability testing conditions. Furthermore, by using the creep constitutive relation and fatigue life model developed in part I, a numerical approach was established for the purpose of virtual life prediction of solder joints. The simulation results were found to be in good agreement with the test results from the MDS. As a result, a new reliability assessment methodology was established as an alternative to ATC for the evaluation of long-term reliability of plastic BGA assembly.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.