Minimally invasive transthoracic device closure of the perimembranous VSD with an asymmetric or a symmetric domestically made device without cardiopulmonary bypass is safe and feasible. It should be considered an acceptable alternative to surgery in selected subgroups. However, it is necessary to evaluate the long-term results.
We describe a modified valve-sparing aortic root replacement technique for acute type A aortic dissection. After the normal root geometry was restored by removing blood and clots in the proximal false lumen and the valve insufficiency was corrected by simple resuspension of the aortic commissures, three teardrop-shaped patches were sutured inside the sinuses as neointima and then in situ coronary buttons were connected to the small holes created in the corresponding patches. Our initial application showed that this modified valve-sparing aortic root replacement technique is an easy and effective way to restore the geometry of the aortic root and avoid bleeding during surgery for acute type A dissection.
BackgroundAtrioventricular block (AVB) is a well-reported complication after closure of perimembranous ventricular septal defects (VSDs). To report the occurrence of AVB either during or following closure of perimembranous VSDs using a novel "hybrid" method involving a minimal inferior median incision and of intraoperative device closure of the perimembranous VSDs.MethodsBetween January 2009 and January 2011, patients diagnosed with perimembranous VSDs eligible for intraoperative device closure with a domestic occluder were identified. All patients were assessed by real-time transesophageal echocardiography (TEE) and electrocardiography.ResultsOf the 97 included patients, 94 were successfully occluded using this approach. Complete AVB occurred in only one case and one case of Mobitz type II AVB was diagnosed intraoperatively. In both patients, the procedure was aborted and the AVBs quickly resolved. Glucocorticosteroids were administered to another two patients who developed Mobitz type II AVB intraoperatively. Those two patients converted to Mobitz type I AVB 3 days and 5 days postsurgically. During the follow-up period (range, 6-24 months), one patient developed complete AVB 1 week following device insertion. Surgical device removal was followed by a rapid and complete recovery of atrioventricular conduction.ConclusionsIntraoperative device closure of perimembranous VSDs with a domestic occluder resulted in excellent closure rates; however, AVB is a serious complication that can occur either during or any time after device closure of perimembranous VSDs. The technique described herein may reduce the incidence of perioperative AVB complications. Surgeons are encouraged to closely monitor all patients postsurgically to ensure AVB does not occur in their patients. Additional long-term data to better identify the prevalence and risk factors for AVB in treated patients are needed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.