Background and PurposeCerebral blood oxygenation level is critical for following the evolution of stroke patients. The purpose of this study was to investigate the feasibility of measuring changes in blood oxygen levels for patients with acute stroke using SWI and to compare these changes with the patient's recovery over time.Materials and MethodsA total 30 MRI scans was performed on 10 acute ischemic stroke patients. Every patient was followed at three time points: less than 24 hours; 2–3 weeks after stroke and 2 months after stroke. Both MRI scan and NIH stroke scale (NIHSS) were acquired for each patient at all three time points. Oxygen saturation changes were derived from phase values differences (Δφ) measured over 10 veins from each hemisphere for all 10 patients over 3 time points. The correlation of oxygen saturation and NIHSS was further evaluated.ResultsThe stroke affected side of the brain showed moderate (r = −0.62) to strong (r = −0.70) correlation between the oxygenation change and NIHSS change. The oxygen saturation change from the normal side of the brain had essentially no association with recovery (r = −0.02 and−0.31). The results suggest that increases in oxygen saturation correspond to improved outcome and reductions in oxygen saturation correspond to worse outcome.ConclusionHigh resolution SWI provided a novel method to measure changes in oxygenation change of the human brain in vivo. By using the phase values from the veins, both spatial and temporal information can be found that relates to patient outcome post stroke.
Application accuracy is a crucial factor for stereotactic surgical localization systems, in which space digitization camera systems are one of the most critical components. In this study we compared the effect of the OPTOTRAK 3020 space digitization system and the FlashPoint Model 3000 and 5000 3D digitizer systems on the application accuracy for interactive localization of intracranial lesions. A phantom was mounted with several implantable frameless markers which were randomly distributed on its surface. The target point was digitized and the coordinates were recorded and compared with reference points. The differences from the reference points represented the deviation from the "true point." The root mean square (RMS) was calculated to show the differences, and a paired t-test was used to analyze the results. The results with the phantom showed that, for 1-mm sections of CT scans, the RMS was 0.76 +/- 0. 54 mm for the OPTOTRAK system, 1.23 +/- 0.53 mm for the FlashPoint Model 3000 3D digitizer system, and 1.00 +/- 0.42 mm for the FlashPoint Model 5000 system. These preliminary results showed that there is no significant difference between the three tracking systems, and, from the quality point of view, they can all be used for image-guided surgery procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.