X‐ray fluorescence (XRF) core‐scanning is a fast and nondestructive technique to assess elemental variations of unprocessed sediments. However, although the exposure time of XRF‐scanning directly affects the scanning counts and total measurement time, only a few studies have considered the influence of exposure time during the scan. How to select an optimal exposure time to achieve reliable results and reduce the total measurement time is an important issue. To address this question, six geological reference materials from the Geological Survey of Japan (JLK‐1, JMS‐1, JMS‐2, JSD‐1, JSD‐2, and JSD‐3) were scanned by the Itrax‐XRF core scanner using the Mo‐ and the Cr‐tube with different exposure times to allow a comparison of scanning counts with absolute concentrations. The regression lines and correlation coefficients of elements that are generally used in paleoenvironmental studies were examined for the different exposure times and X‐ray tubes. The results show that for those elements with relatively high concentrations or high detectability, the correlation coefficients are higher than 0.90 for all exposure times. In contrast, for the low detectability or low concentration elements, the correlation coefficients are relatively low, and improve little with increased exposure time. Therefore, we suggest that the influence of different exposure times is insignificant for the accuracy of the measurements. Thus, caution must be taken when interpreting the results of elements with low detectability, even when the exposure times are long and scanning counts are reasonably high.
Conventional pollution monitoring strategies for heavy metals are often costly and unpractical. Innovative sampling and analytical approaches are therefore needed to efficiently monitor large areas. This study presents a novel, simple, fast, and inexpensive method to monitor heavy metal pollution that uses cation-exchange resin sachets and the micro-XRF core-scanning technique (XRF-CS). The resin passive samplers act as concentrators of cationic species and can be readily deployed spatially and temporally to record pollution signals. The large number of analytical tasks are then overcome by the fast and non-destructive XRF-CS to precisely assess elemental concentrations. Quantifying element loading involves direct comparison with a set of identically prepared and scanned resin reference standards containing Ca, Ti, Cr, Mn, Ni, Cu, Zn, Pb. The results show that within the test range (from 0–1000 s mg kg
−1
), the calibration lines have excellent regressions (R
2
≥ 0.97), even at the shortest exposure time (1 s). A pilot field survey of a suspected polluted area in central Taiwan, where 30 resin sachets had been deployed, identified a pollution hot spot in a rapid and economical manner. Therefore, this approach has the potential to become a valuable tool in environmental monitoring and forensics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.