Objective:The objective of this study is to compare the apical sealability of mineral trioxide aggregate (MTA) Fillapex and Endosequence BC sealer at three different lengths of remaining gutta-percha after postspace preparation.Materials and Methods:A total of 80 freshly extracted human maxillary anterior teeth were decoronated, biomechanically prepared, and randomly divided into four groups; Group A and Group B served as positive and negative control with 10 teeth each. The teeth in Group C and Group D (with 30 teeth each) were obturated with gutta-percha using MTA Fillapex sealer and Endosequence BC sealer, respectively. Teeth in Group C and Group D were further subdivided into three subgroups depending on the length of remaining apical gutta-percha, i.e., 3, 4, and 5 mm after postspace preparation. Apical leakage was assessed using dye penetration method under stereomicroscope.Results:In both the Groups C and D, there was overall no statistically significant difference in leakage; however, Group C showed slightly more leakage than Group D. There was a statistically significant difference in leakage at 3 mm and 5 mm level in both groups.Conclusion:Although less microleakage occurred, the bioceramic sealers could not totally eliminate leakage.
Aim:The present study was aimed to compare the accuracy of Root ZX Mini and Propex II in the presence of 0.1% octinidine dohydrochloride (OCT), 2% chlorhexidine gluconate (CHX), and 5% sodium hypochlorite (NaOCl) heated and nonheated before and after preparation.Materials and Methods:Eighty extracted single-rooted teeth were selected for the study and decoronated. Teeth were mounted in an alginate model. Actual working length (AL) was measured using a stereomicroscope under ×4 magnification. Electronic working length measurements were recorded using Root ZX Mini and Propex II apex locators in the presence of 0.1% OCT, 2% CHX, and 5% NaOCl (nonheated and heated to 60°C) before and after preparation. Mean and standard deviation differences before and after preparation were calculated and statistically analyzed using analysis of variance and paired t-test.Results:The accuracy of Root ZX Mini before and after preparation within ±0.5 mm of AL was consistently high in the presence of irrigants than Propex II. 5% NaOCl (heated and nonheated) showed more variation than the other irrigants, in the working length determination in both the apex locators.Conclusion:Electronic length measurements were shorter with heated and nonheated 5% NaOCl and longer with 0.1% OCT and 2% CHX for both the electronic apex locators.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.