The failure to accurately define tumor margins during breast conserving surgery (BCS) results in a 20% re-excision rate. The present paper reports the investigation to evaluate the potential of terahertz imaging for breast tissue recognition within the under-explored 300 - 600 GHz range. Such a frequency window matches new BiCMOS technology capabilities and thus opens up the opportunity for near-field terahertz imaging using these devices. To assess the efficacy of this frequency band, data from 16 freshly excised breast tissue samples were collected and analyzed directly after excision. Complex refractive indices have been extracted over the as-mentioned frequency band, and amplitude frequency images show some contrast between tissue types. Principal component analysis (PCA) has also been applied to the data in an attempt to automate tissue classification. Our observations suggest that the dielectric response could potentially provide contrast for breast tissue recognition within the 300 - 600 GHz range. These results open the way for silicon-based terahertz subwavelength near field imager design, efficient up to 600 GHz to address ex vivo life-science applications.
Imaging with terahertz (THz) waves has been expected as a non-invasive/non-staining visualization tool for breast cancer margins during surgeries. Breast cancer is a generic name for a heterogeneous lesion comprising invasive adenocarcinoma, in situ adenocarcinoma, most frequently in the form of ductal carcinoma in situ (DCIS) and benign tissues. Until now, THz imaging has focused on invasive adenocarcinoma; however, THz analysis of DCIS has hardly been performed. One of the reasons is that the size of an individual DCIS lesion, ranging from 50 to 500 µm, is typically much smaller than that of an invasive carcinoma. This makes it difficult to identify these lesions by THz imaging, which has only a diffraction-limited spatial resolution of several millimeters. To overcome this drawback, we have developed a scanning point terahertz source (SPoTS) microscope with a resolution of 20 µm, in which a near-infrared-pump-laser-induced two-dimensionally-scannable point THz source (φ THz ≈ φ Pump) generated in a GaAs crystal contacts a sample. In this study, utilizing this state-of-the-art microscope, we mainly performed THz near-field transmission imaging of a paraffin-embedded human breast cancer sample containing invasive carcinoma and DCIS, as a preliminary study. Consequently, for the first time, we succeeded in clearly visualizing a DCIS lesion of ∼φ500 µm in the THz images. It was also found that the THz attenuation by DCIS was higher than that by invasive ductal carcinoma. Furthermore, also in a reflection-mode measurement, we successfully obtained a similar outcome to the above transmission-mode one. These results can be caused by the interaction between the THz waves and the cellular density, indicating that SPoTS microscopy may be suitable for DCIS diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.