Giardia and Cryptosporidium levels were determined by using a combined immunofluorescence test for source waters of 66 surface water treatment plants in 14 states and 1 Canadian province. The results showed that cysts and oocysts were widely dispersed in the aquatic environment. Giardia spp. were detected in 81% of the raw water samples. Cryptosporidium spp. were found in 87% of the raw water locations. Overall, Giardia or Cryptosporidium spp. were detected in 97% of the raw water samples. Higher cyst and oocyst densities were associated with source waters receiving industrial or sewage effluents. Significant correlations were found between Giardia and Cryptosporidium densities and raw water quality parameters such as turbidity and total and fecal coliform levels. Statistical modeling suggests that cyst and oocyst densities could be predicted on the basis of watershed and water quality characteristics. The occurrence of high levels of Giardia cysts in raw water samples may require water utilities to apply treatment beyond that outlined in the Surface Water Treatment Rule of the U.S. Environmental Protection Agency.
The current project was developed to examine inactivation of biofilm bacteria and to characterize the interaction of biocides with pipe surfaces. Unattached bacteria were quite susceptible to the variety of disinfectants tested. Viable bacterial counts were reduced 99% by exposure to 0.08 mg of hypochlorous acid (pH 7.0) per liter (1 to 2°C) for 1 min. For monochloramine, 94 mg/liter was required to kill 99% of the bacteria within 1 min. These results were consistent with those found by other investigators. Biofilm bacteria grown on the surfaces of granular activated carbon particles, metal coupons, or glass microscope slides were 150 to more than 3,000 times more resistant to hypochlorous acid (free chlorine, pH 7.0) than were unattached cells. In contrast, resistance of bioflim bacteria to monochloramine disinfection ranged from 2to 100-fold more than that of unattached cells. The results suggested that, relative to inactivation of unattached bacteria, monochloramine was better able to penetrate and kill biofilm bacteria than free chlorine. For free chlorine, the data indicated that transport of the disinfectant into the biofilm was a major rate-limiting factor. Because of this phenomenon, increasing the level of free chlorine did not increase disinfection efficiency. Experiments where equal weights of disinfectants were used suggested that the greater penetrating power of monochloramine compensated for its limited disinfection activity. These studies showed that monochloramine was as effective as free chlorine for inactivation of biofilm bacteria. The research provides important insights into strategies for control of biofilm bacteria.
Investigations concerning the role of distribution system biofilms on water quality were conducted at a drinking water utility in New Jersey. The utility experienced long-term bacteriological problems in the distribution system, while treatment plant effluents were uniformly negative for coliform bacteria. Results of a monitoring program showed increased coliform levels as the water moved from the treatment plant through the distribution system. Increased coliform densities could not be accounted for by growth of the cells in the water column alone. Identification of coliform bacteria showed that species diversity increased as water flowed through the study area. All materials in the distribution system had high densities of heterotrophic plate count bacteria, while high levels of coliforms were detected only in iron tubercles. Coliform bacteria with the same biochemical profile were found both in distribution system biofilms and in the water column. Assimilable organic carbon determinations showed that carbon levels declined as water flowed through the study area. Maintenance of a 1.0-mg/liter free chlorine residual was insufficient to control coliform occurrences. Flushing and pigging the study area was not an effective control for coliform occurrences in that section. Because coliform bacteria growing in distribution system biofilms may mask the presence of indicator organisms resulting from a true breakdown of treatment barriers, the report recommends that efforts continue to find methods to control growth of coliform bacteria in pipeline biofilms. Ample microscopic evidence is available to show that most pipe surfaces in distribution systems are colonized by microorganisms. Allen et al. (1, 2) showed high populations of bacteria in main encrustations collected from water utilities throughout the United States. Diatoms, algae, and filamentous and rod-shaped bacteria were commonly encountered. In contrast, Ridgway and Olson (35) found that bacteria were sparsely distributed along pipe surfaces they examined. These sparse communities, however, showed a variety of morphologically distinguishable bacterial structures including rodand chain-forming cocci and filamentous and prosthecate cell types. Some organisms were attached to pipe surfaces by extracellular fibrillar appendages. Helical stalks, characteristic of the iron bacterium Gallionella, were observed both in water samples and attached to pipe surfaces (35, 36). Scanning electron microscopy showed that 17% of the 10-to 50-p.m-sized particles were colonized with 10 to 100 bacteria per particle (35). Culture examination of distribution system biofilms has demonstrated large variations in the number of heterotrophic plate count (HPC) bacteria. Olson (31) reported Acinetobacter densities on mortar-lined pipe surfaces as high as 109 bacteria per cm2. Tuovinen and Hsu (40) found viable counts ranging between 40 and 3.1 x 108 bacteria per g in tubercles collected from water distribution pipelines in Columbus, Ohio. Tubercles were found to contain several types of...
Results of our experiments showed that the attachment of bacteria to surfaces provided the greatest increase in disinfection resistance. Attachment of unencapsulated Klebsiella pneumoniae grown in medium with high levels of nutrients to glass microscope slides afforded the microorganisms as much as a 150-fold increase in disinfection resistance. Other mechanisms which increased disinfection resistance included the age of the biofilm, bacterial encapsulation, and previous growth conditions (e.g., growth medium and growth temperature). These factors increased resistance to chlorine from 2-to 10-fold. The choice of disinfectant residual was shown to influence the type of resistance mechanism observed. Disinfection by free chlorine was affected by surfaces, age of the biofilm, encapsulation, and nutrient effects. Disinfection by monochloramine, however, was only affected by surfaces. Importantly, results showed that these resistance mechanisms were multiplicative (i.e., the resistance provided by one mechanism could be multiplied by the resistance provided by a second mechanism).
Regrowth of coliform bacteria in distribution systems has been a problem for a number of water utilities. Efforts to solve the regrowth problem have not been totally successful. The current project, which was conducted at the New Jersey American Water Co.-Swimming River Treatment Plant, showed that the occurrence of coliform bacteria in the distribution system could be associated with rainfall, water temperatures greater than 15°C, total organic carbon levels greater than 2.4 mg/liter, and assimilable organic carbon levels greater than 50 ,ug of acetate carbon equivalents per liter. A multiple linear regression model based on free chlorine residuals present in dead-end sections of the distribution system and temperature predicted 83.8% of the heterotrophic plate count bacterial variation. To limit the growth of coliform bacteria in drinking water, the study concludes that assimilable organic carbon levels should be reduced to <50 ,ug/liter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.