Marking practices are variable and marking is not always used. Introducing standard guidance on marking may reduce the overall risk of wrong site surgery, especially as clinicians work at different hospital sites. However, the more specific needs of people and specialties must also be considered.
The alert was effective in promoting presurgical marking and encouraging awareness of safety issues in relation to correct site surgery. However, care should be taken to monitor unintended consequences and whether change is sustained. Greater flexibility for local adaptation coupled with better design and early testing of safety alerts prior to national dissemination may facilitate more sustainable changes in practice.
In 1991 the West Midlands Pulmonary Function Audit Group examined the consistency between pulmonary function laboratories in the West Midlands. Three healthy subjects visited 22 centres and performed a standard set of pulmonary function tests. Demographic data on nine hypothetical subjects was also supplied for the laboratories to produce predicted values. Equipment was checked for accuracy using standard methods. The 1991 audit revealed significant inter-laboratory variability. Sources of error were identified and after consultation, recommendations were made to improve consistency. In addition, national and regional training workshops were organized for laboratory staff. In 1995 the audit was repeated using the same three subjects. Significant differences continued for all predicted results except for residual volume (RV) and forced vital capacity (FVC) and for all measured results except for functional residual capacity (FRC). However, improvements in the coefficient of variation were seen compared with 1991 for predicted forced expiratory volume (FEV1), total lung capacity (TLC), gas transfer (TLCO), FVC, FRC and RV. Similar improvements were seen in measured results for FEV1 and FVC. Increased variation was seen for predicted corrected transfer factor (KCO) and actual RV. The majority of variables in the 1995 audit had a coefficient of variation of less than 5% between laboratories. Analysis of the predicted results from the hypothetical subjects continued to show unacceptable variation reflecting continuing computer algorithm inconsistency. The improvements seen are encouraging and suggest that a regular audit programme is worthwhile.
Phase 1. Significant variations (P < 0.05) were observed in all measured values of pulmonary function tests of the three subjects. Significant variations (P < 0.05) were also observed in all predicted values except total lung capacity. Phase 2. There were significant variations (P < 0.05) amongst laboratories in calculating the predicted values of all components of pulmonary function tests. No significant differences were observed in the measurement of volume or concentration of carbon monoxide or helium.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.