To investigate the effects of scattered radiation when a thin titanium plate (thickness, 0.05 cm) used for skull fixation in cerebral nerve surgery is irradiated by a 4-MV photon beam. We investigated the dose distribution of radiation inside a phantom that simulates a human head fitted with a thin titanium plate used for post-surgery skull fixation and compared the distribution data measured using detectors, obtained by Monte Carlo (MC) simulations, and calculated using a radiation treatment planning system (TPS). Simulations were shown to accurately represent measured values. The effects of scattered radiation produced by high-Z materials such as titanium are not sufficiently considered currently in TPS dose calculations. Our comparisons show that the dose distribution is affected by scattered radiation around a thin high-Z material. The depth dose is measured and calculated along the central beam axis inside a water phantom with thin titanium plates at various depths. The maximum relative differences between simulation and TPS results on the entrance and exit sides of the plate were 23.1% and – 12.7%, respectively. However, the depth doses do not change in regions deeper than the plate in water. Although titanium is a high-Z material, if the titanium plate used for skull fixation in cerebral nerve surgery is thin, there is a slight change in the dose distribution in regions away from the plate. In addition, we investigated the effects of variation of photon energies, sizes of radiation field and thickness of the plate. When the target to be irradiated is far from the thin titanium plate, the dose differs little from what it would be in the absence of a plate, though the dose escalation existed in front of the metal plate.
SummaryImage-guided radiation therapy using a gold marker-based tumor tracking technique provides precise patient setup and monitoring. However, the marker consists of high-Z material, and the resulting scattered rays tend to have adverse effects on the dose distribution of radiotherapy. The purpose of this study was to evaluate the dosimetric perturbation due to the use of a gold marker for radiotherapy in the lungs. The relative dose distributions were compared with film measurement, Monte Carlo simulation, and XiO calculation with the multi grid superposition algorithm using two types of virtual lung phantoms, which were composed of tough water phantoms, tough lung phantoms, cork boards, and a 2.0-mm-diameter gold ball. No dose increase and decrease in the vicinity of the gold ball was seen in the XiO calculations, although it was seen in the film measurements and the Monte Carlo simulation. The dose perturbation due to a gold marker cannot be evaluated using XiO calculation with the superposition algorithm when the tumor is near a gold marker (especially within 0.5 cm). To rule out the presence of such dose perturbations due to a gold marker, the distance between the gold marker and the tumor must therefore be greater than 0.5 cm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.