Until recently, for mammography Mo anode-Mo filter x-ray tube assemblies were almost exclusively used. Modern mammography units provide the possibility to employ a variety of anode-filter combinations with the aim of adapting the x-ray spectrum to compressed breast thickness and composition. The present contribution provides information on the radiation exposure of two large groups of patients (one of 1678 and one of 945 women) who were mammographed with modern x-ray equipment, and on the dosimetry necessary for the evaluation. For dosimetric purposes spectral information is essential. X-ray spectra have been determined for various anode-filter combinations from measurements with a Ge detector. Based on these spectra, conversion factors from air kerma free in air to average glandular dose (g factors) have been calculated for different anode-filter combinations, compressed breast thickness ranging from 2 to 9 cm and breast compositions varying from 0 to 100% glandular tissue. Determinations of various quantities, including entrance surface air kerma (ESAK), tube output, tube loading (TL), fraction of glandular tissue (FGL) and compressed breast thickness, were made during actual mammography. Average glandular dose (AGD) was determined using g factors corrected for tissue composition as well as g values for standard breast composition, i.e. 50% adipose tissue and 50% glandular tissue by mass. It is shown that, on average, the influence of the actual breast composition causes variations of the order of about 15%. For group 1 and group 2, the mean values of average glandular dose (using g factors corrected for tissue composition) were 1.59 and 2.07 mGy respectively. The number of exposures per woman was on average 3.4 and 3.6 respectively. The mean value of compressed breast thickness was 55.9 and 50.8 mm respectively. The mean age of group 1 was 53.6 years (for group 2 the age was not recorded). The fraction by mass of glandular tissue FGL decrease with increasing compressed breast thickness and age of patient (from 75% at 25 mm to 20% at 80 mm, and from 65% at 20 years to 30% at 75 years). For a medium-sized breast, i.e. a compressed breast thickness of 55 mm, FGL is about 35%, indicating that the standard mix (FGL = 50%) might need some modification, particularly because of additional evidence from another investigation with similar results on FGL.
Uncoated metallic lead is widely used as radiation shielding in research and development, nuclear medicine and radiology, and various manufacturing processes. The common use of lead shielding, however, may present an insidious health hazard due to lead dust. Field and laboratory measurements were collected to evaluate the distribution and removal of lead from radiation shielding material as well as to measure airborne exposures during large shielding emplacement projects. The data indicate that lead is readily dispersed from visibly oxidized as well as freshly-cleaned shielding, but that a single coating of polyurethane can reduce lead removal by nearly three orders of magnitude. Although 8-hour time-weighted average exposures for workers constructing lead shielding structures were nearly all below the Occupational Safety and Health Administration's action level of 30 micrograms/m3 (due to short work periods), the distribution of airborne lead concentrations during this kind of work demonstrates a potential for overexposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.