Summary
Packed ceil volume, haemoglobin concentration, erythrocyte counts, erythrocyte indices, serum iron, iron binding capacities, total and differential leucocyte counts, platelet counts, total plasma protein, fibrinogen, haptoglobin and icterus index values were determined at 14 different ages in eight Thoroughbred and 14 Quarterhorse foals during the first year of life. Absolute neutrophil numbers in blood decreased and lymphocyte numbers increased during the first months. Absolute eosinophil numbers tended to increase until three months old. Haemoglobin concentration and packed cell volume decreased significantly during the first two weeks and generally stayed in the lower portion of adult horse normal ranges during the remainder of the first year. Mean cell volume decreased to minimum values at approximately four months and then gradually increased. Serum iron was high at birth and decreased rapidly to a minimum at three days old. Total iron‐binding capacity increased to a maximum at one month. Serum haptoglobin was generally within the adult normal range at birth. A moderate, but significant, decrease occurred at one week old. Fibrinogen concentration increased to a maximum at five months. Icterus index values decreased rapidly during the first two weeks of life. Minor changes occurred in other parameters measured. Possible causes for the various changes in haematological parameters are discussed.
Although most biochemical values remained relatively constant, significant differences were observed during pregnancy and lactation. Changes in the concentrations of triglycerides, potassium, bilirubin, total CO2, and anion gap during lactation were substantial enough to warrant separate reference intervals for lactating horses.
The in vitro and/or in vivo influences of estrogen and progesterone upon endometrial prostaglandin
F3 (PGF)were evaluated in the intact and in the ovariectomized mare.
Normal reference values for serum proteins of foals from birth to 1 year of age have been established. Chemical and electrophoretic/refractometric methods for total protein, albumin, total globulin and Albumin/Globulin (A/G ratio) have also been compared. The biuret total protein method and Bromcresol Green (BCG) method on the Technicon SMA 12/60 autoanalyzer were used and compared with total protein determined via refractometry and albumin determined by Cellulose Acetate (CA) electrophoresis/densitometry. Globulin and A/G ratios were calculated from the chemical method data and compared with that obtained electrophoretically. Total protein, albumin, total globulins and A/G ratios all were in agreement at all sample times studied. Data on the subfractionation of serum globulins via CA electrophoresis is also presented. Wide variations in alpha and beta globulin levels were noted among the foal sera early in life. As a result, two distinct populations of foals with respect to both globulin content and A/G ratio were identified. One of these populations (Group A) appeared to have obtained passive immunity more slowly than the other (Group B) animals. Comparison of these data with clinical cases of foals in which failure of passive transfer was a part suggests that the A/G ratio may be useful in assessing adequate colostral antibody levels in the newborn foal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.