The solution condition producing the discontinuity for each halide is describable by [Pb2 + ][X-]2 = constant. This effect, not observed in fluoride solutions, is inconsistent with simple anion induced adsorption and is interpreted as a two-dimensional precipitation forming the surface phase PbX2. Chronopotentiometric measurements of the inhibiting properties of adsorbed PbX2 on Hg(ll) reduction and Hg(0), Cd(0), and Zn(0) oxidation are presented to show that the inhibition is the same for electrodeward or solutionward passage through the adsorbed layer. The sudden appearance of the inhibition with increasing lead concentration is independent of the reaction being inhibited and appears to originate in a structural or crystal-perfecting change in the PbX2 surface phase.Data on the adsorption, on mercury electrodes, of white metal cations from aqueous solutions of simple anionic ligands is now fairly extensive. We have available surface excess data for the adsorptions of Cd(II) (1, 2), Hg(II) (3), and Pb(II) (3, 4) from iodide medium; Cd(II) (2), Hg(II) (3), and Pb(II) (3) from bromide medium; Pb(II) (5,6) from chloride medium, Cd(II) (7), Hg(II) (3, 8), Pb(II) (3, 4), In(III) (9), and Zn(II) (6, 10) from thiocyanate medium, Cd(II) (11) from thiosulfate medium, and Cd(II) (12) and Zn(II) (12) from azide medium. Accumulation of these data has been materially aided by development of the double potential step chronocoulometric technique (13) as used with minicomputer control and data acquisition ( 14), the current approach of choice.
recommended to switch back and forth between intermittent and dc operation.In the intermittent mode, the lamp is operated for only a short time, nt, typically 20 X 0.01 sec = 0.2 second for the results in Table II. We found that the light output is the same and so is the stability if n and t are changed within limits to maintain the product constant. For example, if instead of twenty 15-msec pulses, sixty 5-msec pulses are used, output signal is nearly the same value and stability is constant. For short ON-times of less than 2 msec, time delay problems in lamp response and power supply responses can lower reproducibility. In our case, a 4-15 msec ON-time per period proved to be the most appropriate.Measurement Conditions. It is important when making measurements with the hollow cathode lamps to operate under experimental conditions so that sufficient photons are incident on the photomultiplier cathode during the measurement period (12). For example, if a relative standard deviation of 0.1 % is desired for each integration of n pulses, then 10s photon counts must be obtained for the selected hollow cathode time. Thus, the optical throughput and the product nt must be sufficient to provide the required number of photons for the desired precision.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.