PurposeTo evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy.MethodsIn a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP®) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820®).ResultsYAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 (p=0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm (p=0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm (p=0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups (p>0.05).ConclusionYAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant.
ObjectiveTo study the effectiveness of amblyopia screening at ages 3–4.Methods and AnalysisFrom a population with no previous screening, a cohort of 2300 children with 3–4 years old attending school (91% of children this age attend school in Portugal), were submitted to a complete ophthalmological evaluation. Amblyopia was diagnosed, treated and followed. Amblyopia prevalence, treatment effectiveness, absolute risk reduction (ARR), number needed to screen (NNS) and relative risk reduction (RRR) were estimated.ResultsPast/present history of amblyopia was higher than 3.1%–4.2%, depending on amblyopia definition normatives. Screening at age 3–4, had estimated ARR=2.09% (95% CI 1.50% to 2.68%) with a reduced risk of amblyopia in adulthood of 87% (RRR). NNS was 47.8 (95% CI 37.3 to 66.7). Treatment effectiveness of new diagnosis was 88% (83% if we include children already followed). 91% of new amblyopia diagnoses were refractive (of which 100% surpassed amblyopia Multi-Ethnic Pediatric Eye Disease Study criteria after treatment), while most strabismic amblyopias were already treated or undertreatment. Only 30% of children with refractive amblyopia risk factors that were not followed by an ophthalmologist, ended up having amblyopia at age 3–4. Eye patch was needed equally in new-diagnosis versus treated-earlier refractive amblyopia.ConclusionsScreening amblyopia in a whole-population setting at age 3–4 is highly effective. For each 48 children screened at age 3–4, one amblyopia is estimated to be prevented in the future (NNS). Screening earlier may lead to overdiagnosis and overtreatments: Treating all new diagnosis before age 3–4 would have a maximal difference in ARR of 0.3%, with the possible burden of as much as 70% children being unnecessary treated before age 3–4.Involving primary care, with policies for timely referral of suspicious/high-risk preverbal children, plus whole screening at age 3–4 seems a rational/effective way of controlling amblyopia.
A woman aged 60 years developed a Millard-Gubler syndrome after a diagnosis of a cavernous angioma in the median and paramedian areas of the pons. In this context, she presented a right VI nerve palsy, right conjugate gaze palsy, facial palsy and left hemiparesis. To improve the complete VI nerve palsy, we planned a modified transposition approach, in which procedure we made a partial transposition of vertical rectus with a silicone band that was fixated posteriorly. After the procedure, the patient gained the ability to slightly abduct the right eye. We found no compensatory torticollis in the primary position of gaze. There was also an improvement of elevation and depression movements of the right eye. We obtained satisfactory results with a theoretically reversible technique, which is adjustable intraoperatively with no need of muscle detachment, preventing anterior segment ischaemia and allowing simultaneous recession of the medial rectus muscles, if necessary.
Antiphospholipid syndrome is an acquired autoimmune disease characterized by hypercoagulability associated with recurrent venous and arterial thromboembolism in the presence of antiphospholipid antibodies. Herein, we report a case of rapid sequential retinal vein and artery occlusion as the first manifestation of a primary antiphospholipid syndrome triggered by an acute Mycoplasma infection in a previously healthy 11-year-old patient. On day 1, ophthalmoscopy revealed a central retinal vein occlusion. The patient developed temporal branch retinal artery occlusion the next day. On day 3, a central retinal artery occlusion was observed. Serum lupus anticoagulant, immunoglobulin (Ig) G anticardiolipin, IgG anti-β2-glycoprotein 1 antibody, and Mycoplasma pneumoniae IgM antibody levels were increased. Thus, retinal vascular occlusions can be the first manifestation of primary antiphospholipid syndrome. Although it may not improve visual prognosis, prompt diagnosis and treatment are essential to avoid further significant morbidity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.