IMPORTANCEThe prevalence and characteristics of bicuspid aortic valve (BAV) are mainly reported from selected cohorts. BAV is associated with aortopathy, but it is unclear if it represents a fetal developmental defect or is secondary to abnormal valve dynamics.OBJECTIVE To determine the prevalence of BAV and BAV subtypes and to describe the associated aortopathy in a large, population-based cohort of newborns. DESIGN, SETTING, AND PARTICIPANTS The Copenhagen Baby Heart Study was a cross-sectional, population-based study open to all newborns born in Copenhagen between April 1, 2016, and October 31, 2018. Newborns with BAV were matched 1:2 to newborns with a tricuspid aortic valve (non-BAV group) on sex, singleton/twin pregnancy, gestational age, weight, and age at time of examination. EXPOSURES Transthoracic echocardiography within 60 days after birth.MAIN OUTCOMES AND MEASURES Primary outcome was BAV prevalence and types, ie, number of raphes and spatial orientation of raphes or cusps (no raphes), according to the classification system of Sievers and Schmidtke (classified as type 0, 1, or 2, with numbers indicating the number of raphes). Secondary outcome was valve function and BAV-associated aortopathy, defined as aortic diameter z score of 3 or greater or coarctation. RESULTSIn total, 25 556 newborns (51.7% male; mean age, 12 [SD, 8] days) underwent echocardiography. BAV was diagnosed in 196 newborns (prevalence, 0.77% [95% CI, 0.67%-0.88%]), with male-female ratio 2.1:1. BAV was classified as type 0 in 17 newborns (8.7% [95% CI, 5.5%-13.5%]), type 1 in 178 (90.8% [95% CI, 86.0%-94.1%]) (147 [75.0% {95% CI, 68.5%-80.5%}] right-left coronary raphe, 27 [13.8% {95% CI, 9.6%-19.3%}] right coronary-noncoronary raphe, 4 [2.0% {95% CI, 0.8%-5.1%}] left coronary-noncoronary raphe), and type 2 in 1 (0.5% [95% CI, 0.1%-2.8%]). Aortic regurgitation was more prevalent in newborns with BAV (n = 29 [14.7%]) than in those without BAV (1.3%) (absolute % difference, 13.4% [95% CI, 7.8%-18.9%]; P < .001). Newborns with BAV had higher flow velocities across the valve (0.67 [95% CI, 0.65-0.69] m/s vs 0.61 [95% CI, 0.60-0.62] m/s; mean difference, 0.06 m/s [95% CI, 0-0.1]) and larger aortic root and tubular ascending aortic diameters than those without BAV
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.