BackgroundDespite marked benefits in many heart failure patients, a considerable proportion of patients treated with cardiac resynchronization therapy (CRT) fail to respond appropriately. Recently, a “U-shaped” (type II) wall motion pattern identified by cardiovascular magnetic resonance (CMR) has been associated with improved CRT response compared to a homogenous (type I) wall motion pattern. There is also evidence that a left ventricular (LV) lead localized to the latest contracting LV site predicts superior response, compared to an LV lead localized remotely from the latest contracting LV site.MethodsWe prospectively evaluated patients undergoing CRT with pre-procedural CMR to determine the presence of type I and type II wall motion patterns and pre-procedural echocardiography to determine end systolic volume (ESV). We assessed the final LV lead position on post-procedural fluoroscopic images to determine whether the lead was positioned concordant to or remote from the latest contracting LV site. CRT response was defined as a ≥ 15 % reduction in ESV on a 6 month follow-up echocardiogram.ResultsThe study included 33 patients meeting conventional indications for CRT with a mean New York Heart Association class of 2.8 ± 0.4 and mean LV ejection fraction of 28 ± 9 %. Overall, 55 % of patients were echocardiographic responders by ESV criteria. Patients with both a type II pattern and an LV lead concordant to the latest contracting site (T2CL) had a response rate of 92 %, compared to a response rate of 33 % for those without T2CL (p = 0.003). T2CL was the only independent predictor of response on multivariate analysis (odds ratio 18, 95 % confidence interval 1.6-206; p = 0.018). T2CL resulted in significant incremental improvement in prediction of echocardiographic response (increase in the area under the receiver operator curve from 0.69 to 0.84; p = 0.038).ConclusionsThe presence of a type II wall motion pattern on CMR and a concordant LV lead predicts superior CRT response. Improving patient selection by evaluating wall motion pattern and targeting LV lead placement may ultimately improve the response rate to CRT.
BackgroundIt is important to understand the relationship between electrical and mechanical ventricular activation in CRT patients. By measuring local electrical activation at multiple locations within the coronary veins and myocardial contraction at the same locations in the left ventricle, we determined the relationship between electrical and mechanical activation at potential left ventricular pacing locations.MethodsIn this study, mechanical contraction times were computed using high temporal resolution cine cardiovascular magnetic resonance (CMR) data, while electrical activation times were derived from intra-procedural local electrograms.ResultsIn our cohort, there was a strong correlation between electrical and mechanical delay times within each patient (R2 = 0.78 ± 0.23). Additionally, the latest electrically activated location corresponded with the latest mechanically contracting location in 91% of patients.ConclusionsThis study provides initial evidence that our method of obtaining non-invasive mechanical activation patterns accurately reflects the underlying electromechanical substrate of intraventricular dyssynchrony.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.