ECVAM sponsored a formal validation study on three in vitro tests for skin irritation, of which two employ reconstituted human epidermis models (EPISKIN™, EpiDerm™), and one, the skin integrity function test (SIFT), employs ex vivo mouse skin. The goal of the study was to assess whether the in vitro tests would correctly predict in vivo classifications according to the EU classification scheme, “R38” and “no label” (i.e. non-irritant). 58 chemicals (25 irritants and 33 non-irritants) were tested, having been selected to give broad coverage of physico–chemical properties, and an adequate distribution of irritancy scores derived from in vivo rabbit skin irritation tests. In Phase 1, 20 of these chemicals (9 irritants and 11 non-irritants) were tested with coded identities by a single lead laboratory for each of the methods, to confirm the suitability of the protocol improvements introduced after a prevalidation phase. When cell viability (evaluated by the MTT reduction test) was used as the endpoint, the predictive ability of both EpiDerm and EPISKIN was considered sufficient to justify their progression to Phase 2, while the predictive ability of the SIFT was judged to be inadequate. Since both the reconstituted skin models provided false predictions around the in vivo classification border (a rabbit Draize test score of 2), the release of a cytokine, inter-leukin-1α (IL-1α), was also determined. In Phase 2, each human skin model was tested in three laboratories, with 58 chemicals. The main endpoint measured for both EpiDerm and EPISKIN was cell viability. In samples from chemicals which gave MTT assay results above the threshold of 50% viability, IL-1α release was also measured, to determine whether the additional endpoint would improve the predictive ability of the tests. For EPISKIN, the sensitivity was 75% and the specificity was 81% (MTT assay only); with the combination of the MTT and IL-1α assays, the sensitivity increased to 91%, with a specificity of 79%. For EpiDerm, the sensitivity was 57% and the specificity was 85% (MTT assay only), while the predictive capacity of EpiDerm was not improved by the measurement of IL-1α release. Following independent peer review, in April 2007 the ECVAM Scientific Advisory Committee endorsed the scientific validity of the EPISKIN test as a replacement for the rabbit skin irritation method, and of the EpiDerm method for identifying skin irritants as part of a tiered testing strategy. This new alternative approach will probably be the first use of in vitro toxicity testing to replace the Draize rabbit skin irritation test in Europe and internationally, since, in the very near future, new EU and OECD Test Guidelines will be proposed for regulatory acceptance.
A relationship between stratum corneum reservoir function and percutaneous absorption has been established in the hairless rat. Two hundred nanomoles of 10 substances that have a wide range of chemical structures were topically applied for 30 min and the total body distribution was measured after 96 h. The quantity of substance present in the stratum corneum reservoir after 30-min application was measured by liquid scintillation counting after tape-stripping the treated area. A linear relationship exists between the quantity of substance in this reservoir x(nmol X cm-2) and the total amount of radioactivity distributed in the body and excreta y(nmol X cm-2) after 96 h. The relationship is given by: y = 1.644 X x - 0.536 (r = 0.998, p less than 0.001). Apart from the steroids, 80-95% of the compounds were excreted in the urine; and with the exception of thiourea, this elimination was rapid, especially for mannitol and benzoic acid. We confirmed that in terms of penetration there is a factor of 50 between benzoic acid (best) and dexamethasone (worst). Thus the quantity of substance penetrating through intact rat skin can be predicted by measuring the horny layer concentration. The animal data reported here should be verified in humans.
In view of the increasing need to identify non-animal tests able to predict acute skin irritation of chemicals, the European Centre for the Validation of Alternative Methods (ECVAM) focused on the evaluation of appropriate in vitro models. In vitro tests should be capable of discriminating between irritant (I) chemicals (EU risk: R38) and non-irritant (NI) chemicals (EU risk: “no classification”). Since major in vivo skin irritation assays rely on visual scoring, it is still a challenge to correlate in vivo clinical signs with in vitro biochemical measurements. Being particularly suited to test raw materials or chemicals with a wide variety of physical properties, in vitro skin models resembling in vivo human skin were involved in prevalidation processes. Among many other factors, cytotoxicity is known to trigger irritation processes, and can therefore be a first common event for irritants. A refined protocol (protocol15min–18hours) for the EPISKIN model had been proposed for inclusion in the ECVAM formal validation study. A further improvement on this protocol, mainly based on a post-treatment incubation period of 42 hours (protocol15min–42hours), the optimised protocol, was applied to a set of 48 chemicals. The sensitivity, specificity and accuracy with the MTT assay-based prediction model (PM) were 85%, 78.6% and 81.3% respectively, with a low rate of false negatives (12%). The improved performance of this optimised protocol was confirmed by a higher robustness (homogeneity of individual responses) and a better discrimination between the I and NI classes. To improve the MTT viability-based PM, the release of a membrane damage marker, adenylate kinase (AK), and of cytokines IL-1α and IL-8 were also investigated. Combining these endpoints, a simple two-tiered strategy (TTS) was developed, with the MTT assay as the first, sort-out, stage. This resulted in a clear increase in sensitivity to 95%, and a fall in the false-positive rate (to 4.3%), thus demonstrating its usefulness as a “decision-making” tool. The optimised protocol proved, both by its higher performances and by its robustness, to be a good candidate for the validation process, as well as a potential alternative method for assessing acute skin irritation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.