The solubility and the diffusion coefficient of hydrogen were determined in the austenitic (cubic) high-temperature phase of the shape-memory alloy NiTi. The measurements were made between 500 and 950 "C, with hydrogen gas pressures of up to 1.3 bar, and with hydrogen-to-NiTi ratios of up to 0.027. The hydrogen was in interstitial solid solution. The absorption process is exothermic. The enthalpy of solution per hydrogen atom is -183 2 40 meV. The diffusion coefficient can be described by an Arrhenius relation with an activation energy E = 480 -+ 50 meV and a pre-exponential factor Do = (4.7 s) x cmz s-'.NiTi hydride was synthesised in experiments with a higher hydrogen gas pressure ( p = 150 bar, T = 500 K). Because of its brittleness, the hydride is readily pulverised by mechanical methods. This yields, after extraction of the hydrogen, NiTi powder which is difficult to prepare by other experimental techniques.
In an alkaline rebreathing circuit, the inhalation anesthetic sevoflurane degrades into at least two products, one of them being the chiral halodiether 1,1,1,3,3-pentafluoro-2-(fluoromethoxy)-3-methoxypropane (halodiether B). Using octakis(3-O-butanoyl-2,6-di-O-n-pentyl)-y-cyclodextrin (Lipodex E) as chiral host diluted in the polysiloxane PS255, an exceptional large chiral separation factor alpha of 9.7 at 30 degrees C was found for halodiether B by capillary gas chromatography (cGC). Hence, the interaction of the single enantiomers and the racemic mixture of the halodiether B with Lipodex E was selected as a model system to study the enantioselective recognition by thickness shear mode resonators (TSMR), surface acoustic wave sensors, surface plasmon resonance (SPR), and reflectometric interference spectroscopy. Further investigations of the recognition process by using chemical sensors confirmed the preferential enrichment of the S-enantiomer resulting in 9-fold higher signals. Based on the distinction between enantioselective and nonenantioselective sorption, thermodynamic complexation constants of the single enantiomers with Lipodex E could be determined. The difference in Gibbs free energy -deltaE2,E1(deltaG) of the complexation of the enantiomers of halodiether B with pure Lipodex E was determined at 30 degrees C by TSMR and SPR to be 5.7 or 5.9 kJ/mol, respectively, agreeing well with that determined by cGC, i.e., 5.7 kJ/mol at 30 degrees C.
In a rebreathing anesthesia circuit, the inhaled anesthetic sevoflurane degrades into at least two products, termed "compound A" and "compound B." The enantiomer separation of the chiral compound B (1,1,1,3,3-pentafluoro-2-(fluoromethoxy)-3-methoxypropane ) by capillary gas chromatography (cGC) using heptakis (2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl)-beta-cyclodextrin as chiral selector was studied. With this cyclodextrin derivative diluted in the polysiloxane PS 86, an unprecedented high separation factor alpha of 4.1 (at 30 degrees C) was found. Consequently, the enantiomers of compound B were isolated by preparative GC and their specific rotations were measured. In addition, their absolute configurations were determined by X-ray crystallography. To collect the X-ray data, single crystals of both enantiomers were grown in situ on the diffractometer. The levorotatory enantiomer B(-) has the R-configuration while the dextrorotatory enantiomer B(+) has the S-configuration. The elution order of the compound B enantiomers on heptakis (2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl)-beta-cyclodextrin is R before S.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.