Background-Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements. Methods and Results-In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide ϩ30% (condition 2) and at 20 ppm nitric oxide ϩ100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.