Objective: The objective of this work was to evaluate the in vitro release performance of metformin hydrochloride formulations (500-mg tablets) using the hydrodynamic environment of the flow-through cell method. Results were compared with those generated by the official dissolution test (USP basket apparatus). Methods: The reference drug product and three generic formulations were tested with phosphate buffer pH 6.8 as dissolution medium. Dissolution profiles were carried out with an automated flow-through cell apparatus using laminar flow at 16 ml/min. Drug was quantified at 233 nm during 45 min. Dissolution profiles were compared with the calculation of f2 similarity factor, mean dissolution time, dissolution efficiency, t50% and t63.2%. Dissolution data were adjusted to several mathematical models such as Makoid-Banakar, Peppas-Sahlin, Weibull and Logistic. Results: With the flow-through cell method and at 45 min less than 60% of metformin hydrochloride dissolved was found, while with the USP basket apparatus, less than 75% of the drug was found. Some generic formulations showed f2>50 with both USP apparatuses, but statistical comparisons of parameters indicated significant differences between their dissolution profiles and reference. Due to variability obtained no dissolution profiles were compared by model-dependent approach. Conclusion: To demonstrate safe interchangeability between metformin hydrochloride generic formulations and reference bioequivalence studies should be performed. It is important post-marketing monitoring of the commercial formulations because health regulatory agencies of each country must ensure drug products with quality, safety, and efficacy at the lowest possible cost.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright 漏 2024 scite LLC. All rights reserved.
Made with 馃挋 for researchers
Part of the Research Solutions Family.