There was a higher incidence of anterior subcapsular cataract formation in the Adatomed group than in the Staar group. Delayed cataract development and the cataract type in patients with Artisan IOLs indicate that age and axial length may be prognostic factors. Factors such as IOL design, material, and placement probably affect cataract formation in eyes with posterior chamber IOLs for high myopia, particularly the Adatomed IOL.
Several kinds of artificial iris implants are available. In all our patients with aniridia, iris artificial prostheses improved VA and diminished visual discomfort. Glaucoma is the most important complication after artificial iris implant. It is possible to implant the iris prosthesis in the capsular bag, but this requires a large capsulorrhexis and presents a surgical challenge.
PURPOSE: To assess the feasibility of using phakic intraocular lenses (PIOL) to treat high myopia, and evaluate the incidence of cataract, comparing three different lens types.
METHODS: From 1989 to 2002, we implanted three different phakic intraocular lenses (PIOL) in 343 eyes of 232 patients; 231 eyes recieved an Ophtec (Worst-Fechner model, iris-claw), 89 an Adatomed (silicone posterior chamber), and 23 a Staar (posterior chamber, models V2, V3, V4). Average follow-up was 96.2 months for the Ophtec group, 31.5 months for the Adatomed group, and 19.3 months for Staar group. Eyes that subsequently developed cataract were studied for clinical evolution and had PIOL explantation and cataract extraction.
RESULTS: Nuclear cataract developed in 7 of 231 eyes (3.04 %) with an Ophtec lens. Anterior subcapsular cataract developed with the two types of posterior PIOLs (Adatomed group: 38/89 eyes, 42.69%; Staar group: 3/23 eyes, 13.04%). Anterior subcapsular cataract in the Adatomed group developed more rapidly compared to the Staar group. We explanted 7 lenses in the Ophtec group, 16 lenses in the Adatomed group, and 2 lenses in the Staar group (models V2 and V3 only). Patient age older than 40 years at implantation of PIOLs and axial length greater than 30 mm were factors significantly related to nuclear cataract formation and the Ophtec lens. However, these two factors had a weaker correlation with the posterior phakic lenses (Adatomed, Staar) for high myopia than with the Ophtec lens. Postoperative best spectacle -corrected visual acuity remained stable after explantation, phacoemulsification, and posterior chamber lens implantation.
CONCLUSIONS: Delayed cataract development and cataract type (nuclear) in patients with an Ophtec lens and the variables of patient age (>40 yr) and axial length (>30 mm) may considered prognostic factors. Other factors such as lens design, material, and placement probably influenced cataract formation in patients with the Adatomed and Staar PIOLs. The lens styles used in this study are no longer manufactured. [J Refract Surg 2004;20:317-324]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.