A Flux linkage observer (FLO) based sensorless estimation method for permanent magnet BLDC motor based on the integration of back EMF, with a simple start-up method, is proposed here. The rotor position is extracted from the rotor flux information using system equations. The estimated rotor position is improved using a phase locked loop structure which also uses a PI controller for speed estimation. Since the initial rotor position is not known, a simple start up strategy is also introduced. Using a ramp speed reference, an initial rotor position is used for motor control during starting. As the machine picks up speed, control is transferred to flux observer. The control method is validated using simulation results done in MATLAB/Simulink on a 24V, 4000rpm PMBLDC motor.
1. The objective of this study was to evaluate performance of a commercial loop-mediated isothermal amplification (LAMP) method as an alternative method for the detection of Campylobacter spp. in primary production samples, poultry rinses and raw poultry products, as compared to the US
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.