Background. Even though the sensitivity of contrast-enhanced breast magnetic resonance mammography (CE-MRM) is consistently high in the range of 94-100%, conventionally, digital mammography and sonomammography continue as standard imaging modalities for the detection and evaluation of breast disease. The objective of the study was to detect additional lesions that go undetected by routine digital mammography and sonomammography using CE-MRM. Materials and Methods. In a prospective study, 68 patients who came for screening diagnostic mammogram and had breast lesions of Breast Imaging-Reporting and Data System category 3-6 were evaluated. All patients underwent bilateral digital mammography and targeted high-frequency sonomammography of the primary lesion. Those patients who were thought to possibly have breast cancer and to be candidates for surgical management were offered bilateral CE-MRM. Results. In this prospective study, we included 68 patients (mean age - 50.6 years, range - 30-73 years). A total of 74 lesions were evaluated. In detecting these lesions, digital mammography had a sensitivity of 40.0%, specificity of 100% and diagnostic accuracy of 63.5%. CE-MRM sensitivity was found to be 71.7%, specificity - 96.6% and diagnostic accuracy - 83.7%. Among the 27 additional lesions detected by CE-MRM, histopathological evaluation confirmed only 19, indicating the sensitivity of 100%, specificity of 85.4%, positive predictive value of 67.8%, negative predictive value of 100%, diagnostic accuracy of 89.2%. Conclusions. The diagnostic accuracy of CE-MRM was found to be 83.7%, with a specificity of 96.6%. CE-MRM detected 19 additional lesions that were undetected by either digital mammography or ultrasonography. CE-MRM is sensitive in detecting additional malignant lesions which are not detected by other imaging modalities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.