The pitting corrosion resistance of dissimilar pipeline steel API X70 and Super Duplex 2507 Stainless Steel gas tungsten arc (GTA) welds was studied. The GTA welds were fabricated using Super Duplex 2594 Filler Metal or austenitic 309L Filler Metal. The specimens extracted from the base metal, weld fusion zone, fusion boundary, and heat-affected zones (HAZs) were subjected to a potentiodynamic corrosion test in a 3.5% NaCl water solution. The weld made using the 309L Filler Metal was found to have a smaller pitting resistance equivalent number (PREN) difference between ferrite and austenite, making it more corrosion resistant than the weld fabricated using the 2594 Filler Metal. The HAZ on the X70 side was the most susceptible to pitting and galvanic corrosion for both filler metals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.