Abstract. In the present experimental study, the influence of Opening ratio on the chamber temperature in case of vented triangular enclosure with hot base plate has been undertaken. Due to more flow passage, the average air temperature in the enclosure decreases by 12% for OR of 0.25 and 13% for OR of 0.5 compared to OR of 0.125. Similar trend is observed for Rayleigh number with a rise of 73% in OR 0.5 compared to OR of 0.125. Further, the influence of radiation heat transfer in the natural convection based enclosure is also studied. This kind of investigation is useful in the design and analysis of electronic cooling systems.
Abstract. In the present experimental study, the influence of Opening ratio on the chamber temperature in case of vented triangular enclosure with hot base plate has been undertaken. Due to more flow passage, the average air temperature in the enclosure decreases by 12% for OR of 0.25 and 13% for OR of 0.5 compared to OR of 0.125. Similar trend is observed for Rayleigh number with a rise of 73% in OR 0.5 compared to OR of 0.125. Further, the influence of radiation heat transfer in the natural convection based enclosure is also studied. This kind of investigation is useful in the design and analysis of electronic cooling systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.