Ventricular fibrillation can lead to sudden cardiac death. Automatic implantable cardioverter defibrillator (AICD) devices have shown to be highly successful in the termination of these arrhythmias and are a first-line modality of treatment for the prevention of sudden cardiac death. We present the case of a 69-year-old female with a history of paroxysmal atrial fibrillation on anticoagulation with apixaban and rate controlled with metoprolol who presented from home with a chief complaint of hiccups. She had a prior admission to the hospital after she was found to have monomorphic ventricular tachycardia during a nuclear stress test. A cardiac work-up including cardiac catheterization and cardiac magnetic resonance imaging did not show any evidence of significant coronary artery disease or reversible cardiomyopathy. The patient underwent successful placement of a single chamber ICD and was discharged home. Twelve weeks after placement of the AICD, the patient was lifting furniture and experienced sudden onset of hiccups. A chest X-ray showed displacement of the AICD lead from the right ventricular apex to the superior vena cava. The patient underwent lead repositioning with complete resolution of her hiccups. The etiology hiccups was suspected to be secondary to irritation of the right phrenic nerve which travels along the anterolateral border of the superior vena cava. We present the case of hiccups following ICD lead displacement. This serves to highlight a rare complication of ICD displacement that healthcare providers should consider when patients with recently placed ICD devices complain of hiccups.
An 89-year-old man with a history of multiple abdominal surgeries and ventriculoperitoneal (VP) shunt placement for normal pressure hydrocephalus presented for intractable abdominal bloating and scrotal swelling, for which imaging revealed massive ascites, bilateral hydrocele and small bilateral pleural effusions. Cardiac, hepatic and renal workup were insignificant. Culture and cytology of ascitic fluid were negative for infection or malignancy. Aetiology of the ascites as secondary to Cerebrospinal fluid (CSF) from the VP shunt was confirmed via ligation of the shunt. Sterile CSF ascites, hydrothorax and hydrocele are rare complications of VP shunt for hydrocephalus and are mostly presented in paediatric patients. We report the first known case of concurrent CSF ascites, hydrothorax and hydrocele in an elderly patient. We examine the difficulty of shunt replacement as a diagnostic and treatment modality in this age group and propose the use of reversible shunt ligation as a diagnostic modality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.