Polymer stent coatings may not be suitable for drug elution because of inherent proinflammatory effects. A previous study suggested a beneficial effect of a stent eluting tacrolimus from a nanoporous ceramic aluminum oxide coating in a rabbit restenosis model. We investigated whether this stent is effective in preventing in-stent restenosis in a porcine restenosis model. Thirty-four juvenile swine underwent balloon overstretch injury and were subjected to implantation of either stainless steel (bare) stents, bare stents coated with nanoporous aluminum oxide alone, and coated stents eluting 50 and 180 mug of tacrolimus (FK506). In-stent restenosis was quantified at 1 and 3 months after stent placement by histomorphometry. A significant increase of neointimal hyperplasia was noted with the stents coated with aluminum oxide alone compared with bare stents (2.92 +/- 1.02 and 1.38 +/- 0.51 mm(2), respectively; P < 0.02). In all arteries containing coated stents, particle debris was found in the media and neointima, resulting in augmented vascular inflammation. In the group of stents coated with aluminum oxide, FK506 elution at a dose 180 mug reduced neointimal hyperplasia vs. no drug elution (1.66 +/- 0.49 vs. 2.92 +/- 1.02 mm(2); 180 mug vs. ceramic alone; P < 0.03). At a dose of 50 mug stent-based delivery of FK506, no reduction of neointimal hyperplasia was found (2.88 +/- 1.31 and 2.92 +/- 1.02 mm(2), respectively; P = NS; FK506 vs. ceramic alone). In summary, particle debris shed from a drug-eluting aluminum oxide coating of a stainless steel stent counteracts potential antiproliferative effects of stent-based tacrolimus delivery in a porcine model of restenosis. We propose that stent coatings eluting drugs need to be routinely tested for being tightly anchored into the stent surface. Alternatively, omission of any coating used as a drug reservoir may eliminate inflammatory particle debris after placement of drug-eluting stents.
Administration of anti-ICAM-1 mAb following either balloon angioplasty or stent implantation results in a suppression of bFGF in the early phase of restenosis, whereas TGF-beta significantly increases from 7 to 14 days after stent implantation independent of anti-ICAM-1 mAb application. Therefore we conclude that anti-inflammatory strategies are able to interfere with growth factor expression after vascular injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.