A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: 'Is porcine or bovine valve better for aortic valve replacement?' Altogether, 562 papers were found using the reported search, of which 15 represented the best evidence to answer the question. All papers represent either level 1 or 2 evidence. The authors, journal, date, country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. This best evidence paper includes 9880 patients from 1974-2006 to compare both valve types. All studies compared either all or some of the following outcomes: complication, durability, mortality, functional status and haemodynamic function. Ten of 15 papers assessed the complication profile due to aortic valve replacement in both valve types. Four papers concluded that bovine valves are superior, whereas only one favoured porcine valves. Five papers showed a similar complication profile between both valves. Six of 15 papers commented on valve durability. Both porcine and bovine valve groups have two papers each to support their superiority in valve durability. Two papers demonstrated similar durability in both valves. There are 11 papers comparing the postoperative mortality. We suggest that there is no difference in mortality profile as eight papers showed that both valves had similar mortality profiles. Two papers supported bovine valve and one paper supported porcine valve in this aspect. There were four papers assessing the postoperative functional status, with three papers suggesting that both valve types had similar clinical improvement postoperatively. Eleven papers compared the haemodynamic function. Nine papers were in favour of bovine valves. Two papers demonstrated similar haemodynamic profiles in both valves. In conclusion, the bovine valve is superior in its complication and haemodynamic profiles. Both bovine and porcine valves have comparable results with regard to the mortality, postoperative functional status and valve durability. Significant variability between the valve manufacturers, study designs, study period and patient population in the above studies impose limitations to the comparison of both valves.
Plastic surgery encompasses a broad spectrum of reconstructive challenges and prides itself upon developing and adopting new innovations. Practice has transitioned from microsurgery to supermicrosurgery with a possible future role in even smaller surgical frontiers. Exploiting materials on a nanoscale has enabled better visualization and enhancement of biological processes toward better wound healing, tumor identification and viability of tissues, all cornerstones of plastic surgery practice. Recent advances in nanomedicine and biomimicry herald further reconstructive progress facilitating soft and hard tissue, nerve and vascular engineering. These lay the foundation for improved biocompatibility and tissue integration by the optimization of engineered implants or tissues. This review will broadly examine each of these technologies, highlighting areas of progress that reconstructive surgeons may not be familiar with, which could see adoption into our armamentarium in the not-so-distant future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.