Background: Cardioembolic stroke (CES), generally known as the most severe subtype of ischemic stroke, is related to many factors, including diabetes mellitus (DM), hypertension (HTN), smoking, hyperlipidemia and atrial fibrillation (AF). Genetic mutations of the methylenetetrahydrofolate reductase (MTHFR) gene C677T and A1298C have been recently associated with ischemic stroke. The purpose of this study was to analyze the prevalence of MTHFR gene polymorphisms correlated with cardiovascular risk factors in a selected population of patients with CES due to non-valvular AF (NVAF). Methods: This cross-sectional study was performed on 67 consecutive patients with acute cardioembolic stroke admitted to our hospital. The protocol included general physical examination, neurological clinical status and stroke severity evaluation, imagistic evaluation and genetic testing of MTHFRC677T and A1298C polymorphisms. Results: The prevalence of MTHFR polymorphisms in the study population was 38.2% for C677T and 40.3% for A1298C. The C677T mutation was significantly correlated with increased diastolic blood pressure (DBP) values (p = 0.007), higher total cholesterol (TC) (p = 0.003), low-density lipoprotein cholesterol (LDLc) (p = 0.003) and triglycerides (TGL) (p = 0.001), increased high-sensitive C-reactive protein (hsCRP) values (p = 0.015), HbA1c (p = 0.004) and left ventricle ejection fraction (LVEF) (p = 0.047) and lower high-density lipoprotein cholesterol (HDLc) (p < 0.001) compared to patients without this genetic variant. This genetic profile also included significantly higher CHA2DS2VASC (p = 0.029) and HASBLED (Hypertension, Abnormal liver/renal function, Stroke, Bleeding, Labile INR, Elderly age(>65 years), Drug/Alcohol usage history/Medication usage with bleeding predisposition) (p = 0.025) scores. Stroke severity in patients with MTHFRA1298C mutation was significantly increased when applying National Institutes of Health Stroke Scale (NIHSS) (p = 0.006) and modified Rankin scale (mRS) (p = 0.020) scores. The presence of A1298C mutation as a dependent variable was associated with significantly higher TGL values (odds ratio (OR) = 2.983, 95%CI = (1.972, 7.994)). Conclusions: The results obtained in this study demonstrate that MTHFR gene polymorphisms have a high prevalence in an NVAF cardioembolic stroke population. Moreover, an association between C677T mutation and stroke severity was highlighted. The C677T mutation in patients with NVAF was correlated with a higher incidence of cardiovascular comorbidities (hypertension HTN, heart failure (HF), dyslipidemia, type II diabetes mellitus (T2DM) with high HbA1c and increased inflammatory state). The A1298CMTHFR gene mutation was associated with a higher incidence of previous lacunar stroke and stroke recurrence rate, while dyslipidemia was the main cardiovascular comorbidity in this category.
IntroductionCardiac resynchronization therapy (CRT) is known to have very important beneficial effects on heart failure patients. Unfortunately, biventricular implantable cardiac devices (CRT devices), through which this therapy is implemented, are very expensive and sometimes hard to achieve, especially in underdeveloped/developing economies, making this an important problem of public health. As a possible solution, CRT reuse is of great interest nowadays, but unlike simple devices, data in the literature are scarce about biventricular device reuse.AimTo address safety concerns, we aimed to analyze infection burden in the general and elderly population and also early battery depletion and generator malfunction of resterilized biventricular devices compared to new devices.MethodsA cohort of 261 CRT patients (286 devices), who underwent implantation between 2000 and 2014, was retrospectively analyzed. The study group included 115 patients and 127 resterilized devices, that was divided into a subgroup of 69 elderly patients (≥60 years) and 74 devices and a subgroup of 47 younger patients (<60 years) and 53 devices, and the control group included 146 patients and 159 new devices. The groups were compared using a multivariate logistic regression model.ResultsA number of 12 (4.2%) infectious complications were encountered, five (3.9%) in the study group and seven (4.4%) in the control group (odds ratio, 2.83 [0.59–13.44], P=0.189), one (1.3%) in the elderly and four (7.5%) in the younger subgroup (odds ratio, 3.80 [0.36–40.30], P=0.266), with no statistically significant difference between them. There was only one case of early battery depletion, after 17 months, in one study group patient. No generator malfunction was detected.ConclusionReuse of biventricular cardiac implantable electronics seems feasible and safe in both the general population and the elderly population, and it could be a promising alternative when new devices cannot be obtained in a safe period of time.
Aims The safety of pacemaker reuse has been proven by numerous studies in the last two decades. With the exception of one research paper, the safety of reuse of implantable cardioverter‐defibrillators has not been properly investigated. Our aim was to establish whether resterilized implantable cardioverter‐defibrillators are as safe as new devices in relation to functionality and infection rates. Methods All the patients (n = 271) implanted with a new or a donated, used implantable cardioverter‐defibrillator (ICD) at the Institute of Cardiovascular Disease Timisoara Romania between January 2001 and December 2012 were included in the study. The patients had class I indication for ICD implantation. One hundred fifty‐seven patients received reused ICDs and 114 patients received new ICDs. Complications were defined as infections that required reintervention, device malfunction, and replacements due to untimely or unexpected battery depletion. Results Complications occurred in 4.38% of the patients in the new ICD group and in 1.91% of the reused ICD group. The difference was not considered statistically significant (odds ratio 0.28, 95% confidence interval 0.04‐1.82, P = .18). Conclusion According to our data, properly verified and resterilized ICDs are as safe as new devices, when risk of infection or malfunction rates are assessed. Due to the high costs of new ICDs, their safe reuse has profound humanitarian and financial implications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.