In this study, we report the development and validation of an LC-tandem mass spectrometry method for the simultaneous quantitation of bendamustine and copanlisib in mouse plasma as per the US FDA regulatory guidelines. The sample processing involves extraction of bendamustine and copanlisib along with internal standard (IS; warfarin) from 50 μL mouse plasma using a liquid-liquid extraction method. The chromatographic separation of bendamustine, copanlisib and the IS was achieved on an Atlantis dC 18 column using an isocratic mobile phase (5 mM ammonium acetate: methanol, 20:80 v/v). Bendamustine, copanlisib and the IS eluted at 0.88, 1.39 and 0.74 min, respectively, with a total run time of 2.5 min. The calibration curve ranged from 3.99-2996 and 4.33-3248 ng/mL for bendamustine and copanlisib, respectively. Inter-and intra-day precision and accuracy, stability in processed samples and upon storage, dilution integrity and incurred sample reanalysis were investigated for both the analytes. The intra-and inter-day precisions were in the ranges of 2.01%-5.05% and 2.74%-6.13% and 1.98%-7.64 and 8.62%-9.04% for bendamustine and copanlisib, respectively. Stability studies showed that both analytes were stable on bench top for 6 h, in auto-sampler for 24 and at À80 C for 30 days. The validated method was successfully applied to a pharmacokinetic study in mice.
Copanlisib is a dual PI3K‐δ inhibitor, used in follicular lymphoma treatment. In this research, we report a validated LC–MS/MS method for quantifying copanlisib from a mouse dried blood spot (DBS). We validated the method in line with the guidelines of the US Food and Drug Administration. The liquid–liquid extraction technique was used to extract copanlisib from the DBS discs. We used an Atlantis dC18 column and isocratic mobile phase for the chromatographic separation of copanlisib and the internal standard (idelalisib). The flow was 0.90 ml/min. Under the optimized chromatographic conditions, the retentions of copanlisib and the internal standard were 0.98 and 0.93 min, respectively. Each injection total run time was 2.50 min. The MS/MS ion transitions monitored were m/z 481.31 → 128.00 and 416.10 → 176.10 for copanlisib and the internal standard (IS) idelalisib, respectively. We have used a broad calibration range (1.01–4,797 ng/ml) with a determination coefficient (r2) of 0.997. All of the evaluated parameters met the acceptance criteria. Hematocrit did not influence the DBS copanlisib concentrations. We have used the validated method to derive the intravenous pharmacokinetic parameters by quantifying copanlisib in mouse plasma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.