Patients with MD have a high prevalence of both electrical and structural abnormalities. These include reduced LV mass, impaired RV contractility, a high prevalence of LV non-compaction and myocardial fibrosis. These findings illustrate the potential utility of CMR detecting subclinical disease in otherwise asymptomatic patients with MD.
Background: The aim of the current study was to assess the utility of transmurality of delayed enhancement on cardiac magnetic resonance imaging (MRI) in predicting functional recovery in patients with first ST-elevation myocardial infarction (MI) who had received thrombolysis. Methods: Nineteen patients underwent cine and contrast-enhanced MRI 3 days and 8 weeks after MI. The transmural extent of infarction (TEI) was determined from the late enhancement component of the first scan. Segmental wall thickening was scored from the cine components of both the initial and follow-up scans. Results: The TEI was inversely related to the likelihood of improvement in wall thickening; χ2 test for trend = 53.9, p < 0.0001. Delayed enhancement with >50% transmurality predicted a lack of recovery with 82% sensitivity and 54% specificity. The equivalent values for >75% transmurality were 57 and 77%, respectively. The proportion of the left ventricular segments exhibiting functional recovery was related to the percentage of the left ventricle that was severely dysfunctional but had ≤50% TEI (r = 0.49, p = 0.03). In a backward conditional regression model this was the only independent predictor. Conclusion: These data suggest that TEI, determined by contrast-enhanced cardiac MRI, is a useful predictor of the likelihood, or otherwise, of functional recovery following acute MI treated with thrombolysis.
This case report deals with an unusual complication in the removal of an active fixation implantable cardioverter defibrillator (ICD) lead. We were not able to pass the stylet beyond the point of lead fracture and this was subsequently found to be due to the stylet passing between the electrode and the outer layer of the lead insulation. The lead was removed by rotation extraction of the entire lead.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.