Individuals with cancer are vulnerable to infection with SARS-CoV-2, the virus causing COVID-19. Physical distancing, the reallocation of health care resources, and the implementation of procedures to reduce the spread of COVID-19 may also have serious consequences for people with cancer. We evaluated the impact of COVID-19 on new cancer diagnoses and oncology care in Manitoba, Canada using an interrupted time series design and data from the Manitoba Cancer Registry and CancerCare Manitoba’s (CCMB) electronic medical record. In April 2020, there was a 23% decrease in new cancer diagnoses, a 21% decrease in pathology reports, and a 43% reduction in surgical resections. There was no difference in new cancer diagnoses by August 2020, surgery by July 2020, and pathology reports by September 2020. From April 2020 to June 2021, there was a 13% decrease in radiotherapy (RT) fractions, an 18% decrease in UCC visits, and a 52% decrease in in-person visits. There was no change in intravenous chemotherapy visits per month, first RT visits, or overall patient visits. The impact of COVID-19 on shifts in the stage at diagnosis and survival will be assessed in future analyses.
PurposeThree-dimensional printing has been implemented at our institution to create customized treatment accessories, including lead shields used during radiation therapy for facial skin cancer. To effectively use 3-dimensional printing, the topography of the patient must first be acquired. We evaluated a low-cost, structured-light, 3-dimensional, optical scanner to assess the clinical viability of this technology.Methods and materialsFor ease of use, the scanner was mounted to a simple gantry that guided its motion and maintained an optimum distance between the scanner and the object. To characterize the spatial accuracy of the scanner, we used a geometric phantom and an anthropomorphic head phantom. The geometric phantom was machined from plastic and included hemispherical and tetrahedral protrusions that were roughly the dimensions of an average forehead and nose, respectively. Polygon meshes acquired by the optical scanner were compared with meshes generated from high-resolution computed tomography images. Most optical scans contained minor artifacts. Using an algorithm that calculated the distances between the 2 meshes, we found that most of the optical scanner measurements agreed with those from the computed tomography scanner within approximately 1 mm for the geometric phantom and approximately 2 mm for the head phantom. We used this optical scanner along with 3-dimensional printer technology to create custom lead shields for 10 patients receiving orthovoltage treatments of nonmelanoma skin cancers of the face. Patient, tumor, and treatment data were documented.ResultsLead shields created using this approach were accurate, fitting the contours of each patient's face. This process added to patient convenience and addressed potential claustrophobia and medical inability to lie supine.ConclusionsThe scanner was found to be clinically acceptable, and we suggest that the use of an optical scanner and 3-dimensional printer technology become the new standard of care to generate lead shielding for orthovoltage radiation therapy of nonmelanoma facial skin cancer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.