Even in cases of severe medial osteoarthritis and varus malalignment, HTO in combination with a CR procedure is a good to excellent treatment option. The role of the CR procedure remains unclear. Although good results are obtained with overcorrected MPTA, long-term functional outcome is inferior.
IntroductionThis study compared the feasibility of six different CT-based measurement techniques for establishing an indication for derotational osteotomy in the cases of patellar instability or femoral fracture.Materials and methodsCT scans of 52 single human cadaver femora were measured using six different torsion measurement techniques (described by Waidelich, Murphy, and Yoshioka on transverse images and Hernandez, Jarrett, and Yoshioka on oblique images). All measurements were performed by four observers twice to assess intraobserver and interobserver agreement. The intraclass correlation coefficient (ICC), ANOVA, and Bonferroni post hoc test were used for the statistical analysis.ResultsSignificant differences (P < 0.001) between the values for femoral torsion were observed with all techniques except Yoshioka’s techniques on transverse and oblique slices (P = 1.000) (transverse images: Waidelich 22.4° ± 6.8°, Murphy 17.5° ± 7.0°, Yoshioka 13.4° ± 6.9°; oblique images: Hernandez 11.4° ± 7.4°, Jarrett 14.9° ± 7.5°, Yoshioka oblique 13.4° ± 7.1°). Intraobserver and interobserver agreement showed a high level of reproducibility (ICC 0.877–0.986; mean 0.8°–2.9°) for all techniques, with the greatest difference being observed with Hernandez’s technique (11.4°/10°).ConclusionsFemoral torsion values depend on the measurement technique. When derotational osteotomy is being considered, it is essential to use different threshold values depending on the measurement technique.
The results of this biomechanical study suggest that grafts with tibial interference screw fixation provide better knee stability at time zero because of reduced graft elongation and greater stiffness in comparison with grafts with tibial adjustable-length loop cortical button fixation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.