Hypersensitivity pneumonitis was the most common new-onset ILD in India, followed by CTD-ILD and idiopathic pulmonary fibrosis; diagnoses varied between site investigators and CILD experts, emphasizing the value of MDD in ILD diagnosis. Prompted case report forms including environmental exposures in prospective registries will likely provide further insight into the etiology and management of ILD worldwide.
Background: Pleural effusion is a common diagnostic dilemma for the pulmonologist. A histological diagnosis would many a time steer the way to an accurate diagnosis of the aetiologies of pleural effusions. This study has compared two methods for obtaining histological specimens in cases of undiagnosed pleural effusions.
BACKGROUND: Chronic obstructive pulmonary disease (COPD) is common among non-smokers exposed to solid fuel combustion at home. Different clinical characteristics in these patients may have significant therapeutic and prognostic implications.METHODS: We used medical record review and a questionnaire among COPD patients at 15 centres across India to capture data on demographic details, different types of exposures and clinical characteristics. Chest radiography and pulmonary function testing were performed in all 1984 cases; C-reactive protein and exhaled breath nitric oxide were measured wherever available.RESULTS: There were 1388 current or ex-smokers and 596 (30.0%) non-smokers who included 259 (43.5%) male and 337 (56.5%) female patients. Sputum production was significantly more common in smokers with COPD (P < 0.05). The frequency of acute symptomatic worsening, emergency visits and hospitalisation were significantly higher (P < 0.05) in non-smokers with COPD; however, intensive care unit admissions were similar in the two groups. There was no significant difference with respect to the use of bronchodilators, inhalational steroids or home nebulisation among smoker and non-smoker patients. The mean predicted forced expiratory volume in 1 sec in smokers (43.1%) was significantly lower than in non-smokers (46.5%).CONCLUSION: Non-smoker COPD, more commonly observed in women exposed to biomass fuels, was characterised by higher rate of exacerbations and higher healthcare resource utilisation.
Non-resolving pneumonia leading to lung abscess is always a challenge to the treating physician especially in a diabetic patient. Atypical radiological features of lung abscess should raise the suspicion of unusual organisms. This is a case report of a 42 year old diabetic male presented with features suggestive of lung abscess and multiple target organ damage. Subsequent work up revealed that the etiological agent is a rare fungus – Basidiobolus. To the best of our knowledge this is the first case of Basidiobolus lung abscess reported from India.
Context:Multiple environmental factors are associated with development of hypersensitivity pneumonitis (HP), and diagnostic algorithms for the diagnosis of HP have been proposed in recent perspectives.Aims:We analyzed the data of patients with HP from interstitial lung disease (ILD)-India registry. The analysis was performed to (1) find the prevalence of HP, (2) reclassify HP as per a recently proposed classification criterion to assess the level of diagnostic certainty, and (3) identify the causative agents for HP.Setting and Designs:This was a prospective multicenter study of consecutive, consenting adult patients with new-onset ILD from 27 centers across India (March 2012–April 2015).Materials and Methods:The diagnoses were based on prespecified working clinical criteria and multidisciplinary discussions. To assess strength of diagnosis based on available clinical information, patients with HP were subclassified into definite HP, HP with high level of confidence, and HP with low level of confidence using a recent classification scheme.Results:Five hundred and thirteen of 1084 patients with new-onset ILD were clinically diagnosed with HP and subclassified as HP with high level of confidence (380, 74.1%), HP with low level of confidence (106, 20.7%), and definite HP (27, 5.3%). Exposures among patients with HP were birds (odds ratios [OR]: 3.52, P < 0.001), air-conditioners (OR: 2.23, P < 0.001), molds (OR: 1.79, P < 0.001), rural residence (OR: 1.64, P < 0.05), and air-coolers (OR: 1.45, P < 0.05).Conclusions:About 47.3% of patients with new-onset ILD in India were diagnosed with HP, the majority of whom were diagnosed as HP with a high level of confidence. The most common exposures were birds, cooling devices, and visible molds.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.