Evidence for performance decrements following prolonged static stretching (SS) has led to a paradigm shift in stretching routines within a warm-up. Rather than SS, dynamic stretching (DS) and dynamic activity (DA) have replaced SS within warm-up routines. The objective of the present study was to compare the effect of differing lower limb SS durations (30 [SS30s], 60 [SS60s] or 120 s [SS120s] of SS per muscle group or no-stretch control) within a comprehensive warm-up protocol consisting of aerobic activity, DS and DA. Sixteen male participants completed the four stretching conditions in a randomized order, after a 5-min low-intensity (cycle) warm-up and before a DS/DA component on separate days. Tests included passive hip and knee ranges of motion (ROM), maximum voluntary knee extensor/flexor force, force produced at 100 ms (F100), vertical jump height and evoked knee extensor contractile properties. For hip flexion (hamstrings) ROM, SS120s provided the largest increase (5.6-11.7%) followed by SS60s (4.3-11.4%), control (4.4-10.6%) and SS30s (3.6-11.1%). For knee flexion (quadriceps) ROM, SS30s provided the largest increase (9.3-18.2%) followed by SS120s (6.5-16.3%), SS60s (7.2-15.2%) and control (6.3-15.2%). There were decreases in quadriceps F100 following SS in SS120s (29.6%) only. There were increases in vertical jump performance in the control (6.2%), SS60s (4.6%) and SS30s (3.3%). While 120 s SS per muscle increased ROM, even within a comprehensive warm-up routine, it also elicited notable performance decrements. However, moderate durations of SS were observed to improve ROM whilst either having negligible or beneficial (but not detrimental) effects on specific aspects of athletic performance.
The aim of the present study was to investigate the alterations of corticospinal excitability (motor evoked potential, MEP) and inhibition (silent period, SP) following rolling massage of the quadriceps muscles. Transcranial magnetic and femoral nerve electrical stimuli were used to elicit MEPs and compound muscle action potential (Mmax) in the vastus lateralis and vastus medialis muscles prior to and following either (i) 4 sets of 90-s rolling massage (ROLLING) or (ii) rest (CONTROL). One series of neuromuscular evaluations, performed after each set of ROLLING or CONTROL, included 3 MEPs and 1 Mmax elicited every 4 s during 15-s submaximal contractions at 10% (experiment 1, n = 16) and 50% (experiment 2, n = 10) of maximal voluntary knee extensions (MVC). The MEP/Mmax ratio and electromyographic activity recorded from vastus lateralis at 10% MVC demonstrated significantly lower values during ROLLING than CONTROL (P < 0.05). The ROLLING did not elicit any significant changes in muscle excitability (Mmax area) and duration of transcranial magnetic stimulation-induced SP recorded from any muscle or level of contraction (P > 0.05). The findings suggest that rolling massage can modulate the central excitability of the circuitries innervating the knee extensors; however, the observed effects are dependent on the background contraction intensity during which the neuromuscular measurements are recorded.
Adolescent females exhibited an anticipatory response to the task of performing repeated MVCs. A lack of change with knowledge of endpoint indicates that those lacking in MVC experience do not employ the same pacing strategies as in previous studies of participants with MVC experience.
Background. Grab bars are used to support bathing tasks. Sometimes, temporary rim-mounted grab bars may be preferred over permanent wall-mounted grab bars. Purpose. We compared postural requirements, applied loads, and user perceptions between two configurations of rim-mounted grab bars, a vertical wall-mounted grab bar, and a no-grab bar condition. Method. Ten adults entered and exited a simulated bathing environment. Trunk flexion was evaluated via 3D kinematics, while load cells mounted to the grab bars facilitated the evaluation of applied loads. Participants rated each condition on perceived safety, comfort, effectiveness, and ease of use. Findings. Rim-mounted grab bars resulted in greater trunk flexion and greater applied loads and were less favorably perceived. Implications. The rim-mounted grab bars included in this study may induce challenging postural demands and loading scenarios, and occupational therapists should consider whether they meet the needs of their clients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.